CoChat

Updated Reference Standards for Cardiorespiratory Fitness Measured with Cardiopulmonary Exercise Testing

Open access
Kaminsky, Leonard A., Arena, Ross, Myers, Jonathan, Peterman, James E., Bonikowske, Amanda R., Harber, Matthew P., Medina Inojosa, Jose R., Lavie, Carl J., Squires, Ray W. · 2022 · Mayo Clinic Proceedings
Cited by 199

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objective To provide updated reference standards for cardiorespiratory fitness (CRF) for the United States derived from cardiopulmonary exercise (CPX) testing when using a treadmill or cycle ergometer. Patients and Methods Thirty-four laboratories in the United States contributed data to the Fitness Registry and the Importance of Exercise National Database. Analysis included 22,379 tests (16,278 treadmill and 6101 cycle ergometer) conducted between January 1, 1968, through March 31, 2021, from apparently healthy adults (aged 20 to 89 years). Percentiles of peak oxygen consumption for men and women were determined for each decade from 20 through 89 years of age for treadmill and cycle exercise modes, as well as when defining maximal effort as respiratory exchange ratio (RER) greater than or equal to 1.0 or RER greater than or equal to 1.1. Results For both men and women, the 50 th percentile scores for each exercise mode decreased with age and were higher in men across all age groups and higher for treadmill compared with cycle CPX. The average rate of decline per decade over a 6-decade period was 13.5%, 4.0 mLO 2 · kg -1 · min -1 for treadmill CPX and 16.4%, 4.3 mLO 2 · kg -1 · min -1 for cycle CPX. Observationally, the mean peak oxygen consumption was similar whether using an RER criterion of greater than or equal to 1.0 or greater than or equal to 1.1 across the different test modes, ages, and for both sexes. The updated reference standards for treadmill CPX were 1.5 – 4.6 mLO 2 · kg -1 · min -1 lower compared with the previous 2015 standards whereas the updated cycling standards were generally comparable to the original 2017 standards. Conclusion These updated cardiorespiratory fitness reference standards improve the representativeness of the US population compared with the original standards.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.mayocp.2021.08.020

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 199

Metadata

Authors
Kaminsky, L. A., Arena, R., Myers, J., Peterman, J. E., Bonikowske, A. R., Harber, M. P., Medina Inojosa, J. R., Lavie, C. J., & Squires, R. W.
Venue
Mayo Clinic Proceedings
Publisher
Elsevier BV
Published
2022-02
Volume
97
Issue
2
Pages
285-293
ISSN
0025-6196 (ISSN-L)
OpenAlex
W4200172782
Cited by
199
References
6
FWCI
19.08
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.