Real time thermal monitoring of lithium batteries with fiber sensors and thermocouples: A comparative study
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
This work shows a comparative study between the thermocouples and fiber sensors response for the monitoring of temperature variations occurring in three different locations of a lithium battery. The battery is submitted to constant current charge and different discharge rates, under normal and abusive operating conditions. For this specific application, the results show that the fiber Bragg grating sensors have better resolution and a rise time 28.2% lower than the K‐type thermocouples, making them a better choice for the real time monitoring of the battery surface temperature as well as a useful tool for failure detection and an optimized management in batteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An alternative cooling system to enhance the safety of Li-ion battery packs
Kizilel, R., Sabbah, R., Selman, J. R., & Al-Hallaj, S. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2009.06.074 · Cited by 513
Combination of Lightweight Elements and Nanostructured Materials for Batteries
Chen, J., & Cheng, F. (2009) · Accounts of Chemical Research · doi:10.1021/ar800229g · Cited by 502
Li, Z., Zhang, J., Wu, B., Huang, J., Nie, Z., Sun, Y., An, F., & Wu, N. (2013) · Journal of Power Sources · doi:10.1016/j.jpowsour.2013.04.117 · Cited by 192
Real-time temperature measurement with fiber Bragg sensors in lithium batteries for safety usage
Yang, G., Leitão, C., Li, Y., Pinto, J., & Jiang, X. (2013) · Measurement · doi:10.1016/j.measurement.2013.05.027 · Cited by 167
Self-citationSommer, L. W., Kiesel, P., Ganguli, A., Lochbaum, A., Saha, B., Schwartz, J., Bae, C., Alamgir, M., & Raghavan, A. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2015.07.025 · Cited by 124
Wang, P., Zhang, X., Yang, L., Zhang, X., Yang, M., Chen, H., & Fang, D. (2016) · Extreme Mechanics Letters · doi:10.1016/j.eml.2016.03.013 · Cited by 100
Lee, C., Lee, S.-J., Hung, Y.-M., Hsieh, C., Chang, Y.-M., Huang, Y.-T., & Lin, J.-T. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.10.011 · Cited by 88
Yıldız, M., Karakoç, T. H., & Dinçer, İ. (2016) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2016.03.009 · Cited by 28
Lithium batteries temperature and strain fiber monitoring
Nascimento, M. S., Novais, S., Leitão, C., Domingues, M. F., Alberto, N., Antunes, P. F. D. C., & Pinto, J. L. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2195218 · Cited by 25
Self-citation
Cited by
Building Safe Lithium-Ion Batteries for Electric Vehicles: A Review
Duan, J., Tang, X., Dai, H., Yang, Y., Wu, W., Wei, X., & Huang, Y. (2020) · Electrochemical Energy Reviews · doi:10.1007/s41918-019-00060-4 · Cited by 893
A review on various temperature-indication methods for Li-ion batteries
Raijmakers, L. H. J., Danilov, D. L., Eichel, R.-A., & Notten, P. H. L. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.078 · Cited by 424
Dai, H., Jiang, B., Hu, X., Lin, X., Wei, X., & Pecht, M. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110480 · Cited by 405
Mei, W., Liu, Z., Wang, C., Wu, C., Liu, Y., Liu, P., Xia, X., Xue, X., Han, X., Sun, J., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40995-3 · Cited by 405
A survey of methods for monitoring and detecting thermal runaway of lithium-ion batteries
Liao, Z., Zhang, S., Li, K., Zhang, G., & Habetler, T. G. (2019) · Journal of Power Sources · doi:10.1016/j.jpowsour.2019.226879 · Cited by 373
Metadata
- Authors
- Nascimento, M., Ferreira, M. S., & Pinto, J. L.
- Venue
- Measurement
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 111
- Pages
- 260-263
- ISSN
- 0263-2241 (ISSN-L)
- OpenAlex
- W2738215624
- Cited by
- 158
- References
- 9
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.