The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Detection of abnormal heart conditions based on characteristics of ECG signals
Abstract
Abstract Heart diseases are one of the most important death causes across the globe. Therefore, early detection of heart diseases is crucial to reduce the rising death rate. Electrocardiogram (ECG) is widely used to diagnose many types of heart diseases such as abnormal heartbeat rhythm (arrhythmia). However, the non-linearity and the complexity of the abnormal ECG signals make it very difficult to detect its characteristics. Besides, it may be time-consuming to check these ECG signals manually. To overcome these limitations, we have proposed fast and accurate classifier that simulates the diagnosis of the cardiologist to classify the ECG signals into normal and abnormal from a single lead ECG signal and better than other well-known classifiers. First, an accurate algorithm is used for correcting the ECG signals from noise and extracting the major features of each ECG signal. After that, we simulated the characteristics of the ECG signals and created the proposed classifier from these characteristics. Two Neural Network (NN) classifiers, four Support Vector Machine (SVM) classifiers and K-Nearest Neighbor (KNN) classifier are employed to classify the ECG signals and compared with the proposed classifier. The total 13 features extracted from each ECG signal used in the proposed algorithm and set as input to the other classifiers. Our algorithm is validated using all records of MIT-BIH arrhythmia database. Experimental results show that the proposed classifier demonstrates better performance than other classifiers and yielded the highest average classification accuracy of 99%. Thus, our algorithm has the possibility to be implemented in clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Cited by
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Szymczyk-Ziółkowska, P., Łabowska, M. B., Detyna, J., Michalak, I., & Gruber, P. (2020) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2020.01.015 · Cited by 266
Region-of-Interest Based Transfer Learning Assisted Framework for Skin Cancer Detection
Ashraf, R., Afzal, S., Rehman, A. U., Gul, S., Baber, J., Bakhtyar, M., Mehmood, I., Song, O.-Y., & Maqsood, M. (2020) · IEEE Access · doi:10.1109/access.2020.3014701 · Cited by 260
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Zhang, Y., Lai, J., Zhao, C., Wang, J., Yan, Y., Chen, M., Ji, L., Guo, J., Han, B., Shi, Y., et al. (2024) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2024.102992 · Cited by 5
Metadata
- Authors
- Hammad, M., Maher, A., Wang, K., Jiang, F., & Amrani, M.
- Venue
- Measurement
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 125
- Pages
- 634-644
- ISSN
- 0263-2241 (ISSN-L)
- OpenAlex
- W2800884944
- Cited by
- 190
- References
- 2
- FWCI
- 13.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of abnormal heart conditions based on characteristics of ECG signals. https://app.cochat.ai/papers/10.1016/j.measurement.2018.05.033
- The paper
- Hammad, M., Maher, A., Wang, K., Jiang, F., & Amrani, M. (2018). Detection of abnormal heart conditions based on characteristics of ECG signals. Measurement. https://doi.org/10.1016/j.measurement.2018.05.033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.