Deep learning through LSTM classification and regression for transmission line fault detection, diagnosis and location in large-scale multi-machine power systems
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Abstract Fault detection, diagnosis, identification and location are crucial to improve the sensitivity and reliability of system protection. This maintains power systems continuous proper operation; however, it is challenging in large-scale multi-machine power systems. This paper introduces three novel Deep Learning (DL) classification and regression models based on Deep Recurrent Neural Networks (DRNN) for Fault Region Identification (FRI), Fault Type Classification (FTC), and Fault Location Prediction (FLP). These novel models explore full transient data from pre- and post-fault cycles to make reliable decisions; whereas current and voltage signals are measured through Phasor Measurement Units (PMUs) at different terminals and used as input features to the DRNN models. Sequential Deep Learning (SDL) is employed herein through Long Short-Term Memory (LSTM) to model spatiotemporal sequences of high-dimensional multivariate features to achieve accurate classification and prediction results. The proposed algorithms were tested in a Two-Area Four-Machine Power System. Training and testing data are collected during transmission lines faults of different types introduced at various locations in different regions. The presented algorithms achieved superior detection, classification and location performance with high accuracy and robustness compared to contemporary techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Graves, A., Fernández, S., Gomez, F., & Schmidhuber, J. (2006) · Proceedings of the 23rd international conference on Machine learning - ICML '06 · doi:10.1145/1143844.1143891 · Cited by 5,370
Short-Term Residential Load Forecasting Based on LSTM Recurrent Neural Network
Kong, W., Dong, Z. Y., Jia, Y., Hill, D. J., Xu, Y., & Zhang, Y. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2753802 · Cited by 2,645
Zhang, W., Li, C., Peng, G., Chen, Y., & Zhang, Z. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2017.06.022 · Cited by 1,421 · cited 1×
“The cross entropy loss function has been used by the classification layer based on the results of the Softmax cross entropy [39].”
MethodGradient Flow in Recurrent Nets: The Difficulty of Learning LongTerm Dependencies
(2009) · A Field Guide to Dynamical Recurrent Networks · doi:10.1109/9780470544037.ch14 · Cited by 1,246
Selection of representative protein data sets
Hobohm, U., Scharf, M., Schneider, R., & Sander, C. (1992) · Protein Science · doi:10.1002/pro.5560010313 · Cited by 819
Fault diagnosis of wind turbine based on Long Short-term memory networks
Lei, J., Liu, C., & Jiang, D. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.10.031 · Cited by 507
Fault Detection and Classification in Transmission Lines Based on Wavelet Transform and ANN
Silva, K. M., Souza, B. A., & Brito, N. S. D. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.876659 · Cited by 411
Graves, A., Fernández, S., & Gomez, F. (2017) · mediaTUM (Technical University of Munich) · Cited by 386
Sequential Fault Diagnosis Based on LSTM Neural Network
Zhao, H., Sun, S., & Jin, B. (2018) · IEEE Access · doi:10.1109/access.2018.2794765 · Cited by 345
Railway Track Circuit Fault Diagnosis Using Recurrent Neural Networks
de Bruin, T., Verbert, K., & Babuska, R. (2017) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2016.2551940 · Cited by 322
Dash, P. K., Samantaray, S. R., & Panda, G. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.876695 · Cited by 307
Energy Big Data Analytics and Security: Challenges and Opportunities
Hu, J., & Vasilakos, A. V. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2563461 · Cited by 236
Fuzzy-neuro approach to fault classification for transmission line protection
Wang, H., & Keerthipala, W. W. L. (1998) · IEEE Transactions on Power Delivery · doi:10.1109/61.714467 · Cited by 204
Chen, K., Hu, J., & He, J. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2598881 · Cited by 176
Intelligent fault detection of high voltage line based on the Faster R-CNN
Lei, X., & Sui, Z. (2019) · Measurement · doi:10.1016/j.measurement.2019.01.072 · Cited by 172
Liang, J., Jing, T., Huanna, N., & Wang, J. (2020) · IEEE Access · doi:10.1109/access.2020.2980573 · Cited by 144
Zhou, Y., Guo, Q., Sun, H., Yu, Z., Wu, J., & Hao, L. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.11.031 · Cited by 141
Breast Cancer Classification Based on Fully-Connected Layer First Convolutional Neural Networks
Liu, K., Kang, G., Zhang, N., & Hou, B. (2018) · IEEE Access · doi:10.1109/access.2018.2817593 · Cited by 130
Wang, J., & WAN, W. (2008) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2008.10.010 · Cited by 129
Eom, Y. H., Yoo, J. W., Hong, S. B., & Kim, M. S. (2019) · Energy · doi:10.1016/j.energy.2019.115877 · Cited by 123
Appiah, A. Y., Zhang, X., Ayawli, B. B. K., & Kyeremeh, F. (2019) · IEEE Access · doi:10.1109/access.2019.2902949 · Cited by 121
Convolutional neural networks with refined loss functions for the real-time crash risk analysis
Yu, R., Wang, Y., Zou, Z., & Wang, L. (2020) · Transportation Research Part C Emerging Technologies · doi:10.1016/j.trc.2020.102740 · Cited by 111
Sequence labelling in structured domains with hierarchical recurrent neural network
Fernández, S., Graves, A., & Schmidhuber, J. (2008) · mediaTUM (Technical University of Munich) · Cited by 92
Chen, K., Hu, J. P., & He, J. (2017) · IEEE Power & Energy Society General Meeting (PESGM) · doi:10.1109/pesgm.2017.8273992 · Cited by 77
Transmission Line Fault Location Using Deep Learning Techniques
Fan, R., Yin, T., Huang, R., Lian, J. J., & Wang, S. (2019) · North American Power Symposium (NAPS) · doi:10.1109/naps46351.2019.9000224 · Cited by 31
Condition monitoring of offshore wind turbines
Yang, W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100779-2.00018-0 · Cited by 26
Cited by
EskandariNasab, M., Raeisi, Z., Lashaki, R. A., & Najafi, H. (2024) · Scientific Reports · doi:10.1038/s41598-024-58886-y · Cited by 55
“• Long short-term memory (LSTM) : shows great efficiency in feature sequence extraction and data classification in many implementations 82 .”
Background
Metadata
- Authors
- Belagoune, S., Bali, N., Bakdi, A., Baadji, B., & Atif, K.
- Venue
- Measurement
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 177
- Pages
- 109330
- ISSN
- 0263-2241 (ISSN-L)
- OpenAlex
- W3140660742
- Cited by
- 295
- References
- 27
- FWCI
- 21.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.