The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Blood flow and structure interactions in a stented abdominal aortic aneurysm model
Abstract
Since the introduction of endovascular techniques in the early 1990s for the treatment of abdominal aortic aneurysms (AAAs), the insertion of an endovascular graft (EVG) into the affected artery segment has been greatly successful for a certain group of AAA patients and is continuously evolving. However, although minimally invasive endovascular aneurysm repair (EVAR) is very attractive, post-operative complications may occur. Typically, they are the result of excessive fluid-structure interaction dynamics, possibly leading to EVG migration. Considering a 3D stented AAA, a coupled fluid flow and solid mechanics solver was employed to simulate and analyze the interactive dynamics, i.e., pulsatile blood flow in the EVG lumen, pressure levels in the stagnant blood filling the AAA cavity, as well as stresses and displacements in the EVG and AAA walls. The validated numerical results show that a securely placed EVG shields the diseased AAA wall from the pulsatile blood pressure and hence keeps the maximum wall stress 20 times below the wall stress value in the non-stented AAA. The sac pressure is reduced significantly but remains non-zero and transient, caused by the complex fluid-structure interactions between luminal blood flow, EVG wall, stagnant sac blood, and aneurysm wall. The time-varying drag force on the EVG exerted by physiological blood flow is unavoidable, where for patients with severe hypertension the risk of EVG migration is very high.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Cited by
Patient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
Kim, H. J., Vignon-Clementel, I. E., Coogan, J. S., Figueroa, C. A., Jansen, K. E., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0083-6 · Cited by 628
Patient-Specific Modeling of Cardiovascular Mechanics
Taylor, C. A., & Figueroa, C. A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160521 · Cited by 451
On Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model
Kim, H. J., Vignon-Clementel, I. E., Figueroa, C. A., LaDisa, J. F., Jansen, K. E., Feinstein, J. A., & Taylor, C. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9760-8 · Cited by 333
Taylor, C. A., & Steinman, D. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9901-0 · Cited by 261
Computational mechanics of Nitinol stent grafts
Kleinstreuer, C., Li, Z., Basciano, C. A., Seelecke, S., & Farber, M. A. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.032 · Cited by 260
Self-citation
Metadata
- Authors
- Li, Z., & Kleinstreuer, C.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2005-02-12
- Volume
- 27
- Issue
- 5
- Pages
- 369-382
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2025541554
- Cited by
- 170
- References
- 1
- FWCI
- 8.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood flow and structure interactions in a stented abdominal aortic aneurysm model. https://app.cochat.ai/papers/10.1016/j.medengphy.2004.12.003
- The paper
- Li, Z., & Kleinstreuer, C. (2005). Blood flow and structure interactions in a stented abdominal aortic aneurysm model. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2004.12.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.