The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Patient-Specific Modeling of Cardiovascular Mechanics
Open accessAbstract
Advances in numerical methods and three-dimensional imaging techniques have enabled the quantification of cardiovascular mechanics in subject-specific anatomic and physiologic models. Patient-specific models are being used to guide cell culture and animal experiments and test hypotheses related to the role of biomechanical factors in vascular diseases. Furthermore, biomechanical models based on noninvasive medical imaging could provide invaluable data on the in vivo service environment where cardiovascular devices are employed and on the effect of the devices on physiologic function. Finally, patient-specific modeling has enabled an entirely new application of cardiovascular mechanics, namely predicting outcomes of alternate therapeutic interventions for individual patients. We review methods to create anatomic and physiologic models, obtain properties, assign boundary conditions, and solve the equations governing blood flow and vessel wall dynamics. Applications of patient-specific models of cardiovascular mechanics are presented, followed by a discussion of the challenges and opportunities that lie ahead.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Caselles, V., Kimmel, R., & Sapiro, G. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007979827043 · Cited by 5,244
Peskin, C. S. (2002) · Acta Numerica · doi:10.1017/s0962492902000077 · Cited by 4,603
Compensatory Enlargement of Human Atherosclerotic Coronary Arteries
Glagov, S., Weisenberg, E., Zarins, C. K., Stankunavicius, R., & Kolettis, G. J. (1987) · New England Journal of Medicine · doi:10.1056/nejm198705283162204 · Cited by 3,623
Level Set Methods and Fast Marching Methods
Sethian, J. A. (1999) · Medical Entomology and Zoology · Cited by 3,616
Flow patterns around heart valves: A numerical method
Peskin, C. S. (1972) · Journal of Computational Physics · doi:10.1016/0021-9991(72)90065-4 · Cited by 3,047
Verification and Validation in Computational Science and Engineering
Roache, P. J. (1998) · Cited by 2,157
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
A geometric model for active contours in image processing
Caselles, V., Catt�, F., Coll, T., & Dibos, F. (1993) · Numerische Mathematik · doi:10.1007/bf01385685 · Cited by 1,743
Lagrangian-Eulerian finite element formulation for incompressible viscous flows
Hughes, T. J. R., Liu, W. K., & Zimmermann, T. K. (1981) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(81)90049-9 · Cited by 1,524
Cited by
A practical approach to parameter estimation applied to model predicting heart rate regulation
Olufsen, M. S., & Ottesen, J. T. (2013) · Journal of Mathematical Biology · doi:10.1007/s00285-012-0535-8 · Cited by 106
Metadata
- Authors
- Taylor, C. A., & Figueroa, C. A.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 109-134
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2117179898
- Cited by
- 451
- References
- 88
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient-Specific Modeling of Cardiovascular Mechanics. https://app.cochat.ai/papers/10.1146/annurev.bioeng.10.061807.160521
- The paper
- Taylor, C. A., & Figueroa, C. A. (2009). Patient-Specific Modeling of Cardiovascular Mechanics. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev.bioeng.10.061807.160521
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.