CoChat

Distinguishing fall activities from normal activities by angular rate characteristics and high-speed camera characterization

Nyan, M.N., Tay, F.E.H., Tan, A.W.Y., Seah, K.H.W. · 2006 · Medical Engineering & Physics
Cited by 117

The DOI matches its Crossref record.

Abstract

Distinguishing sideways and backward falls from normal activities of daily living using angular rate sensors (gyroscopes) was explored in this paper. Gyroscopes were secured on a shirt at the positions of sternum (S), front of the waist (FW) and right underarm (RU) to measure angular rate in lateral and sagittal planes of the body during falls and normal activities. Moreover, the motions of the fall incidents were captured by a high-speed camera at a frame rate of 250 frames per second (fps) to study the body configuration during fall. The high-speed camera and the sensor data capture system were activated simultaneously to synchronize the picture frame of high-speed camera and the sensor data. The threshold level for each sensor was set to distinguish fall activities from normal activities. Lead time of fall activities (time after threshold value is surpassed to the time when the hip hits the ground) and relative angle of body configuration (angle beta between the vertical line and the line from the center point of the foot or the center point between the two legs to that of the waist) at the threshold level were studied. For sideways falls, lead times of sensors at positions FW and S were about 200-220ms and 135-182ms, respectively. The lead time of the slippery backward fall (about 98ms) from the sensor at position RU was shorter than that of the sideways falls from the sensors at positions FW and S. The relative angle of body configuration at threshold level for sideways and backward falls were about 40-43 degrees for the sensor at position FW, about 43-52 degrees for the sensor at position S and about 54 degrees for the sensor at position RU, respectively. This is the first study that investigates fall dynamics in detection of fall before the person hits the ground using angular rate sensors (gyroscopes).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2005.11.008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 117

Metadata

Authors
Nyan, M. N., Tay, F. E. H., Tan, A. W. Y., & Seah, K. H. W.
Venue
Medical Engineering & Physics
Published
2006-10-01
Volume
28
Issue
8
Pages
842-849
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2034126924
Cited by
117
References
0
FWCI
9.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distinguishing fall activities from normal activities by angular rate characteristics and high-speed camera characterization. https://app.cochat.ai/papers/10.1016/j.medengphy.2005.11.008
The paper
Nyan, M. N., Tay, F. E. H., Tan, A. W. Y., & Seah, K. H. W. (2006). Distinguishing fall activities from normal activities by angular rate characteristics and high-speed camera characterization. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2005.11.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.