Abstract
Distinguishing sideways and backward falls from normal activities of daily living using angular rate sensors (gyroscopes) was explored in this paper. Gyroscopes were secured on a shirt at the positions of sternum (S), front of the waist (FW) and right underarm (RU) to measure angular rate in lateral and sagittal planes of the body during falls and normal activities. Moreover, the motions of the fall incidents were captured by a high-speed camera at a frame rate of 250 frames per second (fps) to study the body configuration during fall. The high-speed camera and the sensor data capture system were activated simultaneously to synchronize the picture frame of high-speed camera and the sensor data. The threshold level for each sensor was set to distinguish fall activities from normal activities. Lead time of fall activities (time after threshold value is surpassed to the time when the hip hits the ground) and relative angle of body configuration (angle beta between the vertical line and the line from the center point of the foot or the center point between the two legs to that of the waist) at the threshold level were studied. For sideways falls, lead times of sensors at positions FW and S were about 200-220ms and 135-182ms, respectively. The lead time of the slippery backward fall (about 98ms) from the sensor at position RU was shorter than that of the sideways falls from the sensors at positions FW and S. The relative angle of body configuration at threshold level for sideways and backward falls were about 40-43 degrees for the sensor at position FW, about 43-52 degrees for the sensor at position S and about 54 degrees for the sensor at position RU, respectively. This is the first study that investigates fall dynamics in detection of fall before the person hits the ground using angular rate sensors (gyroscopes).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey on fall detection: Principles and approaches
Mubashir, M., Shao, L., & Seed, L. (2013) · Neurocomputing · doi:10.1016/j.neucom.2011.09.037 · Cited by 869
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
Bourke, A. K., & Lyons, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.001 · Cited by 509
Comparison of low-complexity fall detection algorithms for body attached accelerometers
Kangas, M., Konttila, A., Lindgren, P., Winblad, I., & Jämsä, T. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.003 · Cited by 493
Evaluation of Accelerometer-Based Fall Detection Algorithms on Real-World Falls
Bagalà, F., Becker, C., Cappello, A., Chiari, L., Aminian, K., Hausdorff, J. M., Zijlstra, W., & Klenk, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037062 · Cited by 464
Magnetic distortion in motion labs, implications for validating inertial magnetic sensors
de Vries, W. H. K., Veeger, H. E. J., Baten, C. T. M., & van der Helm, F. C. T. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.12.004 · Cited by 291
A wearable system for pre-impact fall detection
Nyan, M. N., Tay, F. E. H., & Murugasu, E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.009 · Cited by 241
“A few groups have attempted to detect falls prior to impact (Bourke et al., 2008; Nyan et al., 2006; Wu, 2000).”
BackgroundMethodInfluentialSelf-citationAutomatic Fall Monitoring: A Review
Pannurat, N., Thiemjarus, S., & Nantajeewarawat, E. (2014) · Sensors · doi:10.3390/s140712900 · Cited by 237
“[55] ● [75] ● ● ● ● ● [84] ● ● ● ● ● [52] ● ● ● ● [106] ● [69] ● ● ● ● ● ● [105] ● ● [79] ● ● ● ● [49] ● [70] ● ● ● ● ● ● ● ● [93] ● ● ● ● [53] ● ● ● ● [50] ● ● ● ● ● [98] ● ● ● [101] ● ● ● ● [76] ● ● ● ● ● ● ● ● ● ● ● ● ● [66] ● [46] ● ● ● ● ● ● ● ● [67] ● ● ● ● ● ● ● ● [48] ● ● ● [83] ● ● ● ● [85] ● ● ● ● [92] ● [80…”
BackgroundMethodInfluentialA Wearable Airbag to Prevent Fall Injuries
Tamura, T., Yoshimura, T., Sekine, M., Uchida, M., & Tanaka, O. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033673 · Cited by 223
Fall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
Peetoom, K. K. B., Lexis, M. A. S., Joore, M., Dirksen, C. D., & De Witte, L. P. (2015) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2014.961179 · Cited by 208
From Fall Detection to Fall Prevention: A Generic Classification of Fall-Related Systems
Chaccour, K., Darazi, R., El Hassani, A. H., & Andres, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2628099 · Cited by 207
Ambient Sensors for Elderly Care and Independent Living: A Survey
Uddin, M. Z., Khaksar, W., & Torresen, J. (2018) · Sensors · doi:10.3390/s18072027 · Cited by 166
“[140] (2006) Fall detection A fall detection approach was proposed using gyroscopes.”
MethodFall detection with body-worn sensors: A systematic review
for the FARSEEING Consortium and the FARSEEING Meta Database Consensus Group, Schwickert, L., Becker, C., Lindemann, U., Maréchal, C., Bourke, A., Chiari, L., Helbostad, J. L., Zijlstra, W., Aminian, K., et al. (2013) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s00391-013-0559-8 · Cited by 148
Kangas, M., Vikman, I., Nyberg, L., Korpelainen, R., Lindblom, J., & Jämsä, T. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.016 · Cited by 126
Real-time elderly activity monitoring system based on a tri-axial accelerometer
Kang, D. W., Choi, J. S., Lee, J. W., Chung, S. C., Park, S. J., & Tack, G. R. (2010) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483101003718112 · Cited by 43
Metadata
- Authors
- Nyan, M. N., Tay, F. E. H., Tan, A. W. Y., & Seah, K. H. W.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2006-10-01
- Volume
- 28
- Issue
- 8
- Pages
- 842-849
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2034126924
- Cited by
- 117
- References
- 0
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.