Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The objective of this study was to evaluate and compare tetrahedral and hexahedral finite element meshes of simplified and realistic proximal intact femur geometries. Theoretical expressions of stresses and strains were derived for the simplified model of the femur. For the analysis of the realistic geometry of the proximal femur, a CAD model of the third generation composite femur (Pacific Research Labs, Vashion Island, WA) was used and simulations were performed with Hyperworks (Altair Engineering, Inc., Troy, MI) finite element analysis software. Convergence tests with hexahedral (8- and 20-node brick-elements) and tetrahedral (4- and 10-node tetrahedrons) elements were analysed by comparing the periosteal von Mises stresses and principal strains at a selected point of the femur. The numerical periosteal strains were also compared with experimental ones to determine the accuracy of the finite elements. Overall, we concluded, for the simplified femur, that tetrahedral linear element allowed results more closely to theoretical ones, but hexahedral quadratic elements seem to be more stable and less influenced to the degree of refinement (NDOF) of the mesh. It was not possible to correlate these findings with those observed for the realistic proximal femur simulations where no significant differences were seen using refined meshes, with more than NDOF=20,000 for hexahedral elements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hip contact forces and gait patterns from routine activities
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00040-9 · Cited by 2,215 · cited 1×
“This loading configuration represents the loading situation around the hip during the most strenuous phase of walking and was proposed by Bergmann et al. [29, 30 ] and Heller et al. [31] for mechanical testing of hip replacement reconstructions.”
BackgroundA survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539 · cited 1×
“Finite element models should be sufficiently refined to accurately represent the geometry and mechanical behaviour of the bone structure they simulate [ 12 ,13].”
BackgroundMusculo-skeletal loading conditions at the hip during walking and stair climbing
Heller, M. O., Bergmann, G., Deuretzbacher, G., Dürselen, L., Pohl, M., Claes, L., Haas, N. P., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00039-2 · Cited by 446 · cited 1×
“This loading configuration represents the loading situation around the hip during the most strenuous phase of walking and was proposed by Bergmann et al. [29,30] and Heller et al. [ 31 ] for mechanical testing of hip replacement reconstructions.”
BackgroundA New Method to Analyse the Mechanical Behaviour of Skeletal Parts
Brekelmans, W. A. M., Poort, H. W., & Slooff, T. J. J. H. (1972) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677208998949 · Cited by 291
Stress and strain distribution within the intact femur: compression or bending?
Taylor, M. E., Tanner, K. E., Freeman, M. A. R., & Yettram, A. L. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00031-3 · Cited by 263 · cited 1×
“[4,5]) and seems o be a strong limitation on the quantitative accuracy of finite lement results.”
BackgroundDirect mechanics assessment of elastic symmetries and properties of trabecular bone architecture
van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00093-0 · Cited by 263
Finite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255 · cited 3×
“Musculoskeletal tissues have irregular geometry and so finite element modelling is increasingly carried out using digitised images generated using computer tomography scanning [ 1 ].”
BackgroundMethodInfluentialWalker, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)90000-4 · Cited by 250
A comparative study on different methods of automatic mesh generation of human femurs
Viceconti, M., Bellingeri, L., Cristofolini, L., & Toni, A. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00049-0 · Cited by 217 · cited 2×
“[6–18]) and improvement of hese (see e.”
MethodComputer Methods in Biomechanics and Biomedical Engineering
(2017) · Lecture notes in bioengineering · doi:10.1007/978-3-319-59764-5 · Cited by 133
Cited by
Generalized N-Dimensional Biomechanical Field Analysis Using Statistical Parametric Mapping
Pataky, T. C. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.008 · Cited by 907
Metadata
- Authors
- Ramos, A., & Simões, J. A.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2006-11-01
- Volume
- 28
- Issue
- 9
- Pages
- 916-924
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2032879331
- Cited by
- 207
- References
- 13
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur. https://app.cochat.ai/papers/10.1016/j.medengphy.2005.12.006
- The paper
- Ramos, A., & Simões, J. A. (2006). Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2005.12.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.