Assessment of muscle fatigue using sonomyography: Muscle thickness change detected from ultrasound images
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Muscle fatigue is an exercise-induced reduction in maximal voluntary muscle force. As the surface electromyography (SEMG) can be used to estimate the features of neuromuscular activations associated with muscle contractions, it has been widely employed as an objective tool to evaluate muscle fatigue. On the other hand, ultrasound imaging can inherently provide the morphological information of individual muscle, thus the architectural changes of muscles during fatigue can be obtained. In this study, we demonstrated the feasibility of using the dimensional change of muscles detected by ultrasound images, named as sonomyography (SMG), to characterize the behavior of muscles when they were in fatigue. The SEMG signals of the muscles were also recorded simultaneously and used for comparison. The right biceps brachii muscles of 8 normal young male adult subjects were tested for 30s under 80% of the maximal voluntary isometric contraction. The muscle fatigue was indicated by the change of the root-mean-square (RMS) and median frequency (MDF) of the SEMG signals. The results showed that the SEMG RMS had a linear increase with time with a rate of 2.9+/-1.9%/s (mean+/-S.D.), while the MDF decreased linearly with a rate of -0.60+/-0.26Hz/s. The muscle thickness, detected from the ultrasound images, continuously increased during the muscle fatigue but with a nonlinear increase with time, which was rapid during the initial 8.1+/-2.1s with a mean deformation rate of 0.30+/-0.19%/s and then became slower with a rate of 0.067+/-0.024%/s up to 20s after the contraction. The muscle deformation at 20s was 3.5+/-1.6%. The results demonstrated that the architectural change of muscles detected using SMG could potentially provide complementary information for SEMG for the muscle fatigue assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645 · cited 2×
“INTRODUCTION 14 Muscle fatigue, which is an exercise-induced reduction in maximal voluntary 15 muscle force [1], frequently occurs in our daily life.”
BackgroundMuscle Structure and Theories of Contraction
Huxley, A. F. (1957) · Progress in Biophysics and Biophysical Chemistry · doi:10.1016/s0096-4174(18)30128-8 · Cited by 2,318 · cited 1×
“According to the sliding filament theory of 12 muscle contraction [36], the newly recruited fibers could locally shorten to generate 13 enough force to maintain the torque.”
MethodFUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.560 · Cited by 2,294 · cited 1×
“The “size principle” [35] 9 suggested that more and more motor units might be recruited during the fatigue 10 process in order to compensate the inability of the activated muscle fibers and to 11 maintain their force generation [34].”
BackgroundMyoelectrical manifestations of localized muscular fatigue in humans.
Luca, C. J. D. (1984) · PubMed · Cited by 1,121
Measurement of muscle contraction with ultrasound imaging
Hodges, P. W., Pengel, L. H. M., Herbert, R. D., & Gandevia, S. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10375 · Cited by 816 · cited 2×
“11 Since early 1990’s, sonography has been used to measure the changes in muscle 12 thickness [15][16], muscle fiber pennation angle [17]-[20], muscle fascicle length 13 [15][17]-[20], and muscle cross-sectional area [17][21] during isometric and dynamic 14 contractions.”
BackgroundMethodNarici, M. V., Binzoni, T., Hiltbrand, E., Fasel, J., Terrier, F., & Cerretelli, P. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021685 · Cited by 555
Ultrasonographic assessment of human skeletal muscle size
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0961-9 · Cited by 489 · cited 1×
“11 Since early 1990’s, sonography has been used to measure the changes in muscle 12 thickness [15][16], muscle fiber pennation angle [17]-[20], muscle fascicle length 13 [15][17]-[20], and muscle cross-sectional area [17][21] during isometric and dynamic 14 contractions.”
MethodDetermination of fascicle length and pennation in a contracting human muscle in vivo
Fukunaga, T., Ichinose, Y., Ito, M., Kawakami, Y., & Fukashiro, S. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.354 · Cited by 452
The relationship between EMG and change in thickness of transversus abdominis
McMeeken, J. M., Beith, I. D., Newham, D. J., Milligan, P., & Critchley, D. J. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.01.007 · Cited by 419 · cited 1×
“Some researchers recently began to investigate the relationships 17 between the ultrasound parameters and the EMG activities in quasi-static [15][23][24] 18 and dynamic ways [25][26].”
BackgroundBehavior of motor units in human biceps brachii during a submaximal fatiguing contraction
Garland, S. J., Enoka, R. M., Serrano, L. P., & Robinson, G. A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2411 · Cited by 293 · cited 3×
“The increase of RMS and 9 decrease of MDF as a function of time during the muscle fatigue were consistent with 10 the results previously reported [7][32]-[34].”
BackgroundResultOrizio, C., Gobbo, M., Diemont, B., Esposito, F., & Veicsteinas, A. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0924-1 · Cited by 260
Nonisometric behavior of fascicles during isometric contractions of a human muscle
Ito, M., Kawakami, Y., Ichinose, Y., Fukashiro, S., & Fukunaga, T. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1230 · Cited by 258
Narici, M. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00041-8 · Cited by 229
Nordander, C., Willner, J., Hansson, G.-�., Larsson, B., Unge, J., Granquist, L., & Skerfving, S. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0819-1 · Cited by 215 · cited 1×
“Some researchers recently began to investigate the relationships 17 between the ultrasound parameters and the EMG activities in quasi-static [15][23][24] 18 and dynamic ways [25][26].”
BackgroundYoshitake, Y., Ue, H., Miyazaki, M., & Moritani, T. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210170001 · Cited by 213 · cited 1×
“For example, mechanomyography (MMG) [12]-[14], 9 which detects the sound or vibration generated by muscles during contraction, and 10 near-infrared spectroscopy [13] have been used for the assessment of muscle fatigue.”
MethodPETROFSKY, J. S., GLASER, R. M., PHILLIPS, C. A., LIND, A. R., & WILLIAMS, C. (1982) · Ergonomics · doi:10.1080/00140138208924942 · Cited by 207
Frequency analysis of the surface electromyogram during sustained isometric contractions
Petrofsky, J. S., & Lind, A. R. (1980) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00422448 · Cited by 198 · cited 2×
“The increase of RMS and 9 decrease of MDF as a function of time during the muscle fatigue were consistent with 10 the results previously reported [7][32]-[34].”
BackgroundResultZheng, Y. P., Chan, M. M. F., Shi, J., Chen, X., & Huang, Q. H. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.07.012 · Cited by 181 · cited 15×
“22 The ultrasound system used in this study was the same as that in a previous study 23 on the potential of SMG for prosthesis control [16].”
BackgroundMethodInfluentialSelf-citationSkeletal Muscle Structure, Function and Plasticity
Rogers, D. (2003) · Physiotherapy · doi:10.1016/s0031-9406(05)60189-7 · Cited by 168 · cited 1×
“As these architectural parameters have a close relationship with the 15 muscle functions [22], they can be potentially used to characterize muscle activities 16”
BackgroundRepeated contractions alter the geometry of human skeletal muscle
Maganaris, C. N., Baltzopoulos, V., & Sargeant, A. J. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00604.2002 · Cited by 149 · cited 1×
“11 Since early 1990’s, sonography has been used to measure the changes in muscle 12 thickness [15][16], muscle fiber pennation angle [17]-[20], muscle fascicle length 13 [15][17]-[20], and muscle cross-sectional area [17][21] during isometric and dynamic 14 contractions.”
MethodEsposito, F., Orizio, C., & Veicsteinas, A. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050451 · Cited by 122 · cited 1×
“For example, mechanomyography (MMG) [12]-[14], 9 which detects the sound or vibration generated by muscles during contraction, and 10 near-infrared spectroscopy [13] have been used for the assessment of muscle fatigue.”
MethodKleine, B.-U., Schumann, N.-P., Stegeman, D. F., & Scholle, H. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00306-5 · Cited by 119
Two-dimensional fast magnetic resonance brain segmentation
Suri, J. S. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.940054 · Cited by 95
Human muscle fatigue: frequency dependence of excitation and force generation.
Cooper, R. G., Edwards, R. H. T., Gibson, H., & Stokes, M. J. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017020 · Cited by 91 · cited 1×
“Many methods have been developed to evaluate muscle 19 fatigue, including oxygen uptake [2], heart rate [3], pH value of the muscle interstitial 20 fluid [4], muscle generated force [5], muscle stiffness [6], surface electromyography 21”
MethodChallenging the Role of pH in Skeletal Muscle Fatigue
Stackhouse, S. K., Reisman, D. S., & Binder‐Macleod, S. A. (2001) · Physical Therapy · doi:10.1093/ptj/81.12.1897 · Cited by 80 · cited 1×
“Many methods have been developed to evaluate muscle 19 fatigue, including oxygen uptake [2], heart rate [3], pH value of the muscle interstitial 20 fluid [4], muscle generated force [5], muscle stiffness [6], surface electromyography 21”
MethodMuscle fatigue and calibration of EMG measurements
Öberg, T. (1995) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(96)85582-9 · Cited by 77
Takaishi, T., Ono, T., & Yasuda, Y. (1992) · European Journal of Applied Physiology · doi:10.1007/bf00868137 · Cited by 58
Niels Stensen's geometrical theory of muscle contraction (1667): A reappraisal
Kardel, T. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90310-y · Cited by 51
Effect of muscle fatigue on the compliance of the gastrocnemius medialis tendon and aponeurosis
Mademli, L., Arampatzis, A., & WALSH, M. S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.016 · Cited by 44 · cited 2×
“Only most recently, two papers which 20 examined the muscle architecture with ultrasound during fatigue [25][26] were 21”
BackgroundKimura, T., Hamada, T., Watanabe, T., Maeda, A., Oya, T., & Moritani, T. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1147-9 · Cited by 35 · cited 5×
“This might reflect the fact 18 that the muscle deformation, similar to MMG, is a measure of actuation achieved 19 (mechanical output), while the SEMG is a measure of activation intended (electrical 20 input).”
BackgroundMethodInfluentialSeghers, J., & Spaepen, A. J. (2003) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2003.08.003 · Cited by 35 · cited 2×
“(SEMG) [7][8], and invasive needle EMG [9], etc.”
Background
Cited by
A Nonswelling Hydrogel with Regenerable High Wet Tissue Adhesion for Bioelectronics
Tian, G., Yang, D., Liang, C., Liu, Y., Chen, J., Zhao, Q., Tang, S., Huang, J., Xu, P., Liu, Z., et al. (2023) · Advanced Materials · doi:10.1002/adma.202212302 · Cited by 219
Rehabilitative Ultrasound Imaging of the Posterior Paraspinal Muscles
Stokes, M., Hides, J., Elliott, J., Kiesel, K., & Hodges, P. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2599 · Cited by 169
Testa, S., Fornetti, E., Fuoco, C., Sanchez-Riera, C., Rizzo, F., Ciccotti, M., Cannata, S., Sciarra, T., & Gargioli, C. (2021) · Biomedicines · doi:10.3390/biomedicines9050564 · Cited by 43
Cunningham, R. J., & Loram, I. D. (2020) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0715 · Cited by 36
Intelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Metadata
- Authors
- Shi, J., Zheng, Y. P., Chen, X., & Huang, Q. H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2006-09-05
- Volume
- 29
- Issue
- 4
- Pages
- 472-479
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2117435472
- Cited by
- 165
- References
- 31
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.