Detection of tremor bursts by a running second order moment function and analysis using interburst histograms
The DOI matches its Crossref record.
Abstract
INTRODUCTION: Conventional linear signal processing techniques are not always suitable for the detection of tremor bursts in clinical practice due to inevitable noise from electromyographic (EMG) bursts. This study introduces (1) a non-linear analysis technique based on a running second order moment function (SOMF) and (2) auto- and cross-interburst interval histograms (IBIH) showing distributions of interburst interval EMG bursts of pathological tremors illustrating an application of the SOMF. MATERIALS AND METHODS: EMG recordings from extensors and flexors of two patients with Parkinson's disease with a rest tremor and from a healthy subject during sustained muscular contraction were preliminary analyzed in a pilot study. The SOMF was obtained by repeated second order moment calculations within a window of fixed width W (time scale parameter) plotted as a function of time. Minimum SOMF values indicate local "moments of inertia" of each EMG burst. Bursts were detected and located when minimum SOMF values were below level L (decision parameter). Optimal settings of parameters W and L were calculated empirically for pathological tremor EMGs. Auto- and cross-IBIHs were obtained from minimum SOMF values of detected bursts. RESULTS: Tremor frequency and phase relation between EMG bursts from auto- and cross-IBIHs agreed with those derived from spectral analysis. Burst detection by SOMF has a high sensitivity and selectivity even with noisy background. CONCLUSION: The SOMF is appropriate for detection of individual EMG bursts of pathological tremors. The technique is sensitive to non-stationary changes of tremor bursts regardless of their amplitude. IBIHs provide a measure of tremor frequency and phase difference between EMG bursts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neurological Tremor: Sensors, Signal Processing and Emerging Applications
Grimaldi, G., & Manto, M. (2010) · Sensors · doi:10.3390/s100201399 · Cited by 138
“Editing remains a critical step in digital processing of tremor series [8,67,68].”
BackgroundMethodLinear and nonlinear tremor acceleration characteristics in patients with Parkinson's disease
Meigal, A. Y., Rissanen, S. M., Tarvainen, M. P., Georgiadis, S. D., Karjalainen, P. A., Airaksinen, O., & Kankaanpää, M. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/395 · Cited by 63
“…based on recurrence quantification analysis (RQA), dimensionality based on fractal analysis, and higher order statistics are highly sensitive to hidden rhythms that are characteristic of tremor in PD patients (Fattorini et al 2005, Journée et al 2008, Meigal et al 2009, Rissanen et al 2008).”
MethodIntraoperative neurophysiological assessment of disabling symptoms in DBS surgery
Journee, H. L., Postma, A. A., & Staal, M. J. (2007) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2007.10.006 · Cited by 27
Self-citationShah, A., Coste, J., Lemaire, J.-J., Taub, E., Schüpbach, W. M. M., Pollo, C., Schkommodau, E., Guzman, R., & Hemm-Ode, S. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1559-9 · Cited by 21
“Numerous methods with different sensors, including EMG [2, 15, 17, 25, 44], spirograms [7, 37], and gyroscopes [23, 32, 38], have been used to quantify tremor.”
Method
Metadata
- Authors
- Journée, H. L., Postma, A. A., Sun, M., & Staal, M. J.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2007-02-05
- Volume
- 30
- Issue
- 1
- Pages
- 75-83
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2067558660
- Cited by
- 13
- References
- 0
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.