The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Linear and nonlinear tremor acceleration characteristics in patients with Parkinson's disease
Open accessAbstract
The purpose of the study was to evaluate linear and nonlinear tremor characteristics of the hand in patients with Parkinson's disease (PD) and to compare the results with those of healthy old and young control subjects. Furthermore, the aim was to study correlation between tremor characteristics and clinical signs. A variety of nonlinear (sample entropy, cross-sample entropy, recurrence rate, determinism and correlation dimension) and linear (amplitude, spectral peak frequency and total power, and coherence) hand tremor parameters were computed from acceleration measurements for PD patients (n = 30, 68.3 ± 7.8 years), and old (n = 20, 64.2 ± 7.0 years) and young (n = 20, 18.4 ± 1.1 years) control subjects. Nonlinear tremor parameters such as determinism, sample entropy and cross-sample entropy were significantly different between the PD patients and healthy controls. These parameters correlated with the Unified Parkinson's disease rating scale (UPDRS), tremor and finger tapping scores, but not with the rigidity scores. Linear tremor parameters such as the amplitude and the maximum power (power corresponding to peak frequency) also correlated with the clinical findings. No major difference was detected in the tremor characteristics between old and young control subjects. The study revealed that tremor in PD patients is more deterministic and regular when compared to old or young healthy controls. The nonlinear tremor parameters can differentiate patients with PD from healthy control subjects and these parameters may have potential in the assessment of the severity of PD (UPDRS).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sample entropy of hand tremor was proved significantly different between the PD patients and healthy controls [35].”
From Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data (2021) · cites this paper as [35]
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 2×
“The differential diagnostics of PD and ET is still complicated (Jankovic 2008).”
BackgroundAn advanced detrending method with application to HRV analysis
Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979357 · Cited by 1,131
Self-citationThe cerebral oscillatory network of parkinsonian resting tremor
Timmermann, L., Gross, J., Dirks, M., Volkmann, J., Freund, H.-J., & Schnitzler, A. (2003) · Brain · doi:10.1093/brain/awg022 · Cited by 544 · cited 1×
“Cerebral oscillatory networks can contribute to abnormal synchronization of neural activity in the generation of resting tremor in PD (Timmermann et al 2003, McAuley and Marsden 2000, Sturman et al 2004).”
BackgroundPhysiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
Motor unit firing rates and contractile properties in tibialis anterior of young and old men
Connelly, D. M., Rice, C. L., Roos, M. R., & Vandervoort, A. A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.843 · Cited by 340
Motor unit discharge and force tremor in skill- and strength-trained individuals
Semmler, J. G., & Nordstrom, M. A. (1998) · Experimental Brain Research · doi:10.1007/s002210050316 · Cited by 237
Load-Independent Contributions From Motor-Unit Synchronization to Human Physiological Tremor
Halliday, D. M., Conway, B. A., Farmer, S. F., & Rosenberg, J. R. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.2.664 · Cited by 224
The dynamics of resting and postural tremor in Parkinson's disease
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00467-3 · Cited by 210
Resting state oscillatory brain dynamics in Parkinson’s disease: An MEG study
Bosboom, J. L. W., Stoffers, D., Stam, C. J., van Dijk, B. W., Verbunt, J., Berendse, H. W., & Wolters, E. C. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.06.720 · Cited by 200
Research works printed but not linked: 1
- Nieminen H, 1996, Electromyogr. Clin. Neurophysiol., 36, 49
Cited by
Automatic Classification of Tremor Severity in Parkinson’s Disease Using a Wearable Device
Jeon, H., Lee, W., Park, H.-Y., Lee, H. X., Kim, S., Kim, H., Jeon, B., & Park, K. J. (2017) · Sensors · doi:10.3390/s17092067 · Cited by 164
Kim, H. B., Lee, W. W., Kim, A., Lee, H. J., Park, H. Y., Jeon, H. S., Kim, S. K., Jeon, B., & Park, K. S. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.02.007 · Cited by 124
Non-Linear EMG Parameters for Differential and Early Diagnostics of Parkinson’s Disease
Meigal, A. Y., Rissanen, S. M., Tarvainen, M. P., Airaksinen, O., Kankaanpaa, M. J., & Karjalainen, P. A. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00135 · Cited by 65
“Acceleration signal demonstrated a very much the same correlation with loads, UPDRS, and motor symptoms as the sEMG signal (61).”
BackgroundMethodResultInfluentialSelf-citationA-WEAR Bracelet for Detection of Hand Tremor and Bradykinesia in Parkinson’s Patients
Channa, A., Ifrim, R., Popescu, D., & Popescu, N. (2021) · Sensors · doi:10.3390/s21030981 · Cited by 70
EMG signal morphology and kinematic parameters in essential tremor and Parkinson’s disease patients
Ruonala, V., Meigal, A. Y., Rissanen, S. M., Airaksinen, O., Kankaanpaa, M. J., & Karjalainen, P. A. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2013.12.007 · Cited by 63
“In patients with Parkinson’s disease, sample entropy has been measured to be lower than in controls (Meigal et al., 2012).”
BackgroundSelf-citation
Metadata
- Authors
- Meigal, A. Y., Rissanen, S. M., Tarvainen, M. P., Georgiadis, S. D., Karjalainen, P. A., Airaksinen, O., & Kankaanpää, M.
- Affiliations
- Petrozavodsk State University (RU)
- University of Eastern Finland (FI)
- Kuopio University Hospital (FI)
- Corresponding author
- Meigal, A Yu
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-02-28
- Volume
- 33
- Issue
- 3
- Pages
- 395-412
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2068582089
- Cited by
- 63
- References
- 37
- Citations by year
- 2026: 2 · 2024: 6 · 2023: 4 · 2022: 6 · 2021: 7 · 2020: 6 · 2019: 5 · 2018: 8 · 2017: 3 · 2016: 2 · 2015: 5 · 2014: 5 · 2013: 4
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Tekes
- Kuopion Yliopistollinen Sairaala
- Topics
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- Parkinson's disease, hand tremor, sample entropy, cross-sample entropy, recurrence rate, determinism, correlation dimension, tremor amplitude, Unified Parkinson's Disease Rating Scale, tremor severity assessment, aging
- MeSH terms
- Acceleration, Aged, Aged, 80 and over, Antiparkinson Agents, Female, Humans, Male, Middle Aged, Muscle Rigidity, Parkinson Disease, Severity of Illness Index, Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Linear and nonlinear tremor acceleration characteristics in patients with Parkinson's disease. https://app.cochat.ai/papers/10.1088/0967-3334/33/3/395
- The paper
- Meigal, A. Y., Rissanen, S. M., Tarvainen, M. P., Georgiadis, S. D., Karjalainen, P. A., Airaksinen, O., & Kankaanpää, M. (2012). Linear and nonlinear tremor acceleration characteristics in patients with Parkinson's disease. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/3/395
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.