Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We have investigated the use of an Artificial Neural Network (ANN) for the assessment of fall-risk (FR) in patients with different neural pathologies. The assessment integrates a clinical tool based on a wearable device (WD) with accelerometers (ACCs) and rate gyroscopes (GYROs) properly suited to identify trunk kinematic parameters that can be measured during a posturography test with different constraints. Our ANN--a Multi Layer Perceptron Neural Network with four layers and 272 neurones--shows to be able to classify patients in three well-known fall-risk levels. The training of the neural network was carried on three groups of 30 subjects with different Fall-Risk Tinetti scores. The validation of our neural network was carried out on three groups of 100 subjects with different Fall-Risk Tinetti scores and this validation demonstrated that the neural network had high specificity (> or =0.88); sensitivity (> or =0.87); area under Receiver-Operator Characteristic Curves (>0.854).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Massion, J. (1994) · Current Opinion in Neurobiology · doi:10.1016/0959-4388(94)90137-6 · Cited by 747 · cited 1×
“A p ( A f t t © K 1 c a t i s o e s m r ( T a a a 1 d Available online at www.sciencedirect.com Medical Engineering & Physics 30 (2008) 367–372 Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography Daniele Giansanti a,∗, Giovanni…”
Method
Cited by
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Bonato, P. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936554 · Cited by 423
Review of fall risk assessment in geriatric populations using inertial sensors
Howcroft, J., Kofman, J., & Lemaire, E. D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-91 · Cited by 377
Smart Devices for Older Adults Managing Chronic Disease: A Scoping Review
Kim, B. Y., & Lee, J. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7141 · Cited by 217
“Another study employed a neural network to predict falls based on kinematic parameters collected from a smart wearable device [98].”
Application of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
Metadata
- Authors
- Giansanti, D., Maccioni, G., Cesinaro, S., Benvenuti, F., & Macellari, V.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2007-06-08
- Volume
- 30
- Issue
- 3
- Pages
- 367-372
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2006580519
- Cited by
- 69
- References
- 1
- FWCI
- 16.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography. https://app.cochat.ai/papers/10.1016/j.medengphy.2007.04.006
- The paper
- Giansanti, D., Maccioni, G., Cesinaro, S., Benvenuti, F., & Macellari, V. (2008). Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2007.04.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.