Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality

MacNeil, Joshua A., Boyd, Steven K.·2008·Medical Engineering & Physics

Abstract

A human high-resolution peripheral quantitative computed tomography scanner (HR-pQCT) (XtremeCT, Scanco Medical, Switzerland) capable of measuring three important indicators of bone quality (micro-architectural morphology, mineralization and mechanical stiffness) has been developed. The goal of this study was to evaluate the reproducibility of male and female HR-pQCT in vivo measurements, and elucidate the causes of error in these measurements through a comparison with in vitro measurements. The best possible short-term reproducibility was found using a set of 10 in vitro measurements without repositioning, and a set of 10 with repositioning. Subsequently, in vivo measurements were performed on 15 male and 15 female subjects at baseline and follow-ups of 1 week and 4 months to determine the short- and long-term reproducibility of the system. In addition to the 2D area matching method used in the standard evaluation protocol, a custom developed 3D registration method was used to find the common region between repeated scans. The best possible reproducibility without movement artifacts and repositioning error was less than 0.5%, while the reproducibility with repositioning error was less than 1.5%. The in vivo reproducibility of density (<1%), morphological (<4.5%) and stiffness (<3.5) measurements was consistently poorer than the reproducibility of cadaver measurements, presumably due to small movement artifacts and repositioning errors. Using 3D image registration, repositioning error was reduced on average by 23% and 8% for measurements of the radius and tibia sites, respectively. This study has provided bounds for the reproducibility of HR-pQCT to monitor bone quality longitudinally, and a basis for clinical study design to determine detectable changes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2007.11.003

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 230

Metadata

Authors
MacNeil, J. A., & Boyd, S. K.
Venue
Medical Engineering & Physics
Published
2008-07-01
Volume
30
Issue
6
Pages
792-799
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2099326137
Cited by
230
References
2
FWCI
12.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality. https://app.cochat.ai/papers/10.1016/j.medengphy.2007.11.003
The paper
MacNeil, J. A., & Boyd, S. K. (2008). Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2007.11.003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.