The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality
Abstract
A human high-resolution peripheral quantitative computed tomography scanner (HR-pQCT) (XtremeCT, Scanco Medical, Switzerland) capable of measuring three important indicators of bone quality (micro-architectural morphology, mineralization and mechanical stiffness) has been developed. The goal of this study was to evaluate the reproducibility of male and female HR-pQCT in vivo measurements, and elucidate the causes of error in these measurements through a comparison with in vitro measurements. The best possible short-term reproducibility was found using a set of 10 in vitro measurements without repositioning, and a set of 10 with repositioning. Subsequently, in vivo measurements were performed on 15 male and 15 female subjects at baseline and follow-ups of 1 week and 4 months to determine the short- and long-term reproducibility of the system. In addition to the 2D area matching method used in the standard evaluation protocol, a custom developed 3D registration method was used to find the common region between repeated scans. The best possible reproducibility without movement artifacts and repositioning error was less than 0.5%, while the reproducibility with repositioning error was less than 1.5%. The in vivo reproducibility of density (<1%), morphological (<4.5%) and stiffness (<3.5) measurements was consistently poorer than the reproducibility of cadaver measurements, presumably due to small movement artifacts and repositioning errors. Using 3D image registration, repositioning error was reduced on average by 23% and 8% for measurements of the radius and tibia sites, respectively. This study has provided bounds for the reproducibility of HR-pQCT to monitor bone quality longitudinally, and a basis for clinical study design to determine detectable changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osteoporosis Prevention, Diagnosis, and Therapy
NIH Consensus Development Panel on Osteoporosis Prevention, D. (2001) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.285.6.785 · Cited by 5,529
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Cited by
Macdonald, H. M., Nishiyama, K. K., Kang, J., Hanley, D. A., & Boyd, S. K. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.171 · Cited by 375
Self-citationRapid cortical bone loss in patients with chronic kidney disease
Nickolas, T. L., Stein, E. M., Dworakowski, E., Nishiyama, K. K., Komandah-Kosseh, M., Zhang, C. A., McMahon, D. J., Liu, X. S., Boutroy, S., Cremers, S., et al. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1916 · Cited by 352
Nilsson, A. G., Sundh, D., Bäckhed, F., & Lorentzon, M. (2018) · Journal of Internal Medicine · doi:10.1111/joim.12805 · Cited by 323
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Pialat, J., Burghardt, A. J., Sode, M., Link, T. M., & Majumdar, S. (2012) · Bone · doi:10.1016/j.bone.2011.10.003 · Cited by 295
Metadata
- Authors
- MacNeil, J. A., & Boyd, S. K.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2008-07-01
- Volume
- 30
- Issue
- 6
- Pages
- 792-799
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2099326137
- Cited by
- 230
- References
- 2
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality. https://app.cochat.ai/papers/10.1016/j.medengphy.2007.11.003
- The paper
- MacNeil, J. A., & Boyd, S. K. (2008). Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2007.11.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.