Stimulator selection in SSVEP-based BCI
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Steady-state visual evoked potentials (SSVEP) are increasingly used in the development of brain-computer interface techniques (BCI). We investigated the spectrum differences of three kinds of flickers and the differences in SSVEPs evoked by three different stimulators, i.e. the light-emitting diode, the cathode ray tube of a desktop monitor and the liquid crystal display of a laptop screen. The results showed that the SSVEP differences were strongly related to the frequency spectrum differences of the flickers. According to these differences, the stimulator was selected based on the complexity of the BCI system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 4×
“The light-emitting diode LED) flicker is able to evoke an SSVEP in a frequency range f 1–90 Hz [4].”
BackgroundResultInfluential
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“The stimulation decision can be made on the basis of the number of choices that the BCI offers [115].”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
A Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
A high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
Metadata
- Authors
- Wu, Z., Lai, Y., Xia, Y., Wu, D., & Yao, D.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2008-03-07
- Volume
- 30
- Issue
- 8
- Pages
- 1079-1088
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2071609345
- Cited by
- 192
- References
- 1
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stimulator selection in SSVEP-based BCI. https://app.cochat.ai/papers/10.1016/j.medengphy.2008.01.004
- The paper
- Wu, Z., Lai, Y., Xia, Y., Wu, D., & Yao, D. (2008). Stimulator selection in SSVEP-based BCI. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2008.01.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.