Technical variability of the GT3X accelerometer
Abstract
To analyze the intra- and inter-instrument reliability of the ActiGraph GT3X accelerometer using a vibration table on each orthogonal axis and at five frequencies of motion. Ten GT3X units were subjected to a specific vibration using a motorized vibration table along the vertical, horizontal right-left and horizontal front-back axis, and at 1.1, 2.1, 3.1, 4.1 and 10.2 Hz. The 5 min data for each frequency were analyzed separately for frequency, axis effects, and inter- and intra-instrument variability. We found overall high intra-and inter-instrument reliability for the GT3X accelerometer at frequencies between 2.1 and 4.1 Hz. For frequencies ranging between 2.1 and 4.1 Hz, the intra-instrument coefficient of variation was ≤2.5%. The inter-instrument coefficient of variation ranged widely along axes and frequencies, with the lowest values (≤9%) corresponding to 2.1-4.1 Hz. The intra-class correlation coefficient for activity counts across frequencies and for all axes was 0.97. Overall, our findings support the use of the GT3X accelerometer as an accurate tool to estimate free-living physical activity, at least within those frequencies that are common to most types of human daily activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Accelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174
Modeling Physical Activity Outcomes from Wearable Monitors
HEIL, D. P., BRAGE, S., & ROTHNEY, M. P. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399dcc · Cited by 121
Cited by
Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions
Aadland, E., & Ylvisåker, E. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134606 · Cited by 313
Aguilar-Farías, N., Brown, W. J., & Peeters, G. M. E. E. (. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.07.002 · Cited by 306
Metadata
- Authors
- Santos-Lozano, A., Marín, P. J., Torres-Luque, G., Ruiz, J. R., Lucía, A., & Garatachea, N.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2012-03-12
- Volume
- 34
- Issue
- 6
- Pages
- 787-790
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2143073005
- Cited by
- 180
- References
- 5
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.