Accelerometer Output and MET Values of Common Physical Activities
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PURPOSE: This article 1) provides the calibration procedures and methods for metabolic and activity monitor data collection, 2) compares measured MET values to the MET values from the compendium of physical activities, and 3) examines the relationship between accelerometer output and METs for a range of physical activities. METHODS: Participants (N = 277) completed 11 activities for 7 min each from a menu of 23 physical activities. Oxygen consumption (V O2) was measured using a portable metabolic system, and an accelerometer was worn. MET values were defined as measured METs (V O2/measured resting metabolic rate) and standard METs (V O2/3.5 mL.kg.min). For the total sample and by subgroup (age [young < 40 yr], sex, and body mass index [normal weight < 25 kg.m]), measured METs and standard METs were compared with the compendium, using 95% confidence intervals to determine statistical significance (alpha = 0.05). Average counts per minute for each activity and the linear association between counts per minute and METs are presented. RESULTS: Compendium METs were different than measured METs for 17/21 activities (81%). The number of activities different than the compendium was similar between subgroups or when standard METs were used. The average counts for the activities ranged from 11 counts per minute (dishes) to 7490 counts per minute (treadmill: 2.23 m.s, 3%). The r between counts and METs was 0.65. CONCLUSIONS: This study provides valuable information about data collection, metabolic responses, and accelerometer output for common physical activities in a diverse participant sample. The compendium should be updated with additional empirical data, and linear regression models are inappropriate for accurately predicting METs from accelerometer output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The robust association between VT and RPE 12-13 also extends to exercise testing and prescription in patients under the influence of Β-blockers, where the intensity at VT was confirmed with HR-based determinations of relative intensity (35).”
From Ventilatory Threshold Related to VO2reserve, Heart Rate Reserve, and Rating of Perceived Exertion in a Large Varied Sample (2023) · cites this paper as [35]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“if VT cannot be measured, then RPE is well established as a useful metric to prescribe and monitor exercise intensity (34,35).”
From Ventilatory Threshold Related to VO2reserve, Heart Rate Reserve, and Rating of Perceived Exertion in a Large Varied Sample (2023) · cites this paper as [35]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497 · cited 2×
“The compendium standardizes subjective measurements by assigning MET values for over 600 activities, which allows researchers to compare data across studies (3).”
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 4×
“However, linear regression models are still commonly used (36), and more research is needed to understand the magnitude and the source of error when linear processing techniques are developed on a diverse sample of activities.”
InfluentialCompendium of Physical Activities: Classification of energy costs of human physical activities
AINSWORTH, B. E., HASKELL, W. L., LEON, A. S., JACOBS, D. R., MONTOYE, H. J., SALLIS, J. F., & PAFFENBARGER, R. S. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199301000-00011 · Cited by 4,102 · cited 1×
“Although these techniques are susceptible to researcher and subject bias, the validity of self-report measures was enhanced by the development of the compendium of physical activities (2,3).”
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“The most commonly used technique, the linear regression model, was developed on the basis of the premise EE increases linearly with vertical acceleration in locomotion activities (14).”
Self-citationAssessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Revision of the Physical Activity Readiness Questionnaire (PAR-Q).
Thomas, S. G., Reading, J., & Shephard, R. J. (1992) · PubMed · Cited by 1,989
Compher, C., Frankenfield, D., Keim, N., & Roth-Yousey, L. (2006) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.02.009 · Cited by 923 · cited 1×
“The protocol used for measurement of RMR is consistent with published recommendations (10).”
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Development of a Compendium of Energy Expenditures for Youth.
Ridley, K., Ainsworth, B. E., & Olds, T. S. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-45 · Cited by 598
(2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.2008.00136.x · Cited by 593
Cited by
2011 Compendium of Physical Activities: A Second Update of Codes and MET Values
AINSWORTH, B. E., HASKELL, W. L., HERRMANN, S. D., MECKES, N., BASSETT, D. R., TUDOR-LOCKE, C., GREER, J. L., VEZINA, J., WHITT-GLOVER, M. C., & LEON, A. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821ece12 · Cited by 6,317
“denote 1 MET for calculating the activity MET listed in the Compendium, especially when assessing the energy cost of PA in individuals (9,22,23).”
Validation of Wearable Monitors for Assessing Sedentary Behavior
KOZEY-KEADLE, S., LIBERTINE, A., LYDEN, K., STAUDENMAYER, J., & FREEDSON, P. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820ce174 · Cited by 905
Self-citationThe Reliability of MinimaxX Accelerometers for Measuring Physical Activity in Australian Football
Boyd, L. J., Ball, K., & Aughey, R. J. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.311 · Cited by 556
Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
Santos-Lozano, A., Santín-Medeiros, F., Cardon, G., Torres-Luque, G., Bailón, R., Bergmeir, C., Ruiz, J., Lucia, A., & Garatachea, N. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1337945 · Cited by 383
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
“Actigraph Model GT1M Actigraph LLC Pensacola, FL F [48-50] + L [29,49,51-57] 3.”
Background
Metadata
- Authors
- KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S.
- Affiliations
- University of Massachusetts Amherst (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2010-09
- Volume
- 42
- Issue
- 9
- Pages
- 1776-1784
- ISSN
- 0195-9131 (ISSN-L)
- PMC
- PMC2924952
- OpenAlex
- W2090518821
- Cited by
- 174
- References
- 34
- Citations by year
- 2026: 8 · 2025: 4 · 2024: 2 · 2023: 10 · 2022: 5 · 2021: 12 · 2020: 11 · 2019: 14 · 2018: 8 · 2017: 9 · 2016: 8 · 2015: 12 · 2014: 21 · 2013: 18 · 2012: 10
- FWCI
- 10.83
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA121005)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- MET values, physical activity, oxygen consumption, accelerometer calibration, activity counts, energy expenditure, accelerometer validity
- MeSH terms
- Acceleration, Adult, Calibration, Energy Metabolism, Exercise Test, Humans, Male, Middle Aged, Monitoring, Physiologic, Motor Activity, Oxygen Consumption, Body Mass Index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerometer Output and MET Values of Common Physical Activities. https://app.cochat.ai/papers/10.1249/mss.0b013e3181d479f2
- The paper
- KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010). Accelerometer Output and MET Values of Common Physical Activities. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e3181d479f2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.