Dual-mode artificially-intelligent diagnosis of breast tumours in shear-wave elastography and B-mode ultrasound using deep polynomial networks
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The main goal of this study is to build an artificial intelligence (AI) architecture for automated extraction of dual-modal image features from both shear-wave elastography (SWE) and B-mode ultrasound, and to evaluate the AI architecture for classification between benign and malignant breast tumors. In this AI architecture, ultrasound images were segmented by the reaction diffusion level set model combined with the Gabor-based anisotropic diffusion algorithm. Then morphological features and texture features were extracted from SWE and B-mode ultrasound images at the contourlet domain. Finally, we employed a framework for feature learning and classification with the deep polynomial network (DPN) on dual-modal features to distinguish between malignant and benign breast tumors. With the leave-one-out cross validation, the DPN method on dual-modal features achieved a sensitivity of 97.8%, a specificity of 94.1%, an accuracy of 95.6%, a Youden's index of 91.9% and an area under the receiver operating characteristic curve of 0.961, which was superior to the classic single-modal methods, and the dual-modal methods using the principal component analysis and multiple kernel learning. These results have demonstrated that the dual-modal AI-based technique with DPN has the potential for breast tumor classification in future clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A deep learning framework for supporting the classification of breast lesions in ultrasound images
Han, S., Kang, H.-K., Jeong, J.-Y., Park, M.-H., Kim, W., Bang, W.-C., & Seong, Y.-K. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa82ec · Cited by 358
Deep learning based classification of breast tumors with shear-wave elastography
Zhang, Q., Xiao, Y., Dai, W., Suo, J., Wang, C., Shi, J., & Zheng, H. (2016) · Ultrasonics · doi:10.1016/j.ultras.2016.08.004 · Cited by 240
Self-citationShi, J., Zhou, S., Liu, X., Zhang, Q., Lu, M., & Wang, T. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.01.074 · Cited by 166
Self-citationTowards automated semantic segmentation in prenatal volumetric ultrasound
Yang, X., Yu, L., Li, S., Wen, H., Luo, D., Bian, C., Qin, J., Ni, D., & Heng, P.-A. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2858779 · Cited by 115
Cited by
Deep learning for Alzheimer's disease diagnosis: A survey
Khojaste-Sarakhsi, M., Haghighi, S. S., Ghomi, S. M. T. F., & Marchiori, E. (2022) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102332 · Cited by 194
Deep learning in ultrasound elastography imaging: A review
Li, H., Bhatt, M., Qu, Z., Zhang, S., Hartel, M. C., Khademhosseini, A., & Cloutier, G. (2022) · Medical Physics · doi:10.1002/mp.15856 · Cited by 47
Pfob, A., Sidey-Gibbons, C., Barr, R. G., Duda, V., Alwafai, Z., Balleyguier, C., Clevert, D.-A., Fastner, S., Gomez, C., Goncalo, M., et al. (2022) · European Journal of Cancer · doi:10.1016/j.ejca.2022.09.018 · Cited by 27
Metadata
- Authors
- Zhang, Q., Song, S., Xiao, Y., Chen, S., Shi, J., & Zheng, H.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2018-12-19
- Volume
- 64
- Issue
- 1
- Pages
- 1-6
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2903967284
- Cited by
- 57
- References
- 4
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.