Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography

Open access
Kirişli, H.A., Schaap, M., Metz, C.T., Dharampal, A.S., Meijboom, W.B., Papadopoulou, S.L., Dedic, A., Nieman, K., de Graaf, M.A., Meijs, M.F.L., Cramer, M.J., Broersen, A., Cetin, S., Eslami, A., Flórez-Valencia, L., Lor, K.L., Matuszewski, B., Melki, I., Mohr, B., Öksüz, I., Shahzad, R., Wang, C., Kitslaar, P.H., Unal, G., Katouzian, A., Orkisz, M., Chen, C.M., Precioso, F., Najman, L., Masood, S., Ünay, D., van Vliet, L., Moreno, R., Goldenberg, R., Vuçini, E., Krestin, G.P., Niessen, W.J., van Walsum, T.·2013·Medical Image Analysis

Abstract

Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2013.05.007

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 205

Metadata

Authors
Kirişli, H. A., Schaap, M., Metz, C. T., Dharampal, A. S., Meijboom, W. B., Papadopoulou, S. L., Dedic, A., Nieman, K., de Graaf, M. A., Meijs, M. F. L., Cramer, M. J., Broersen, A., Cetin, S., Eslami, A., Flórez-Valencia, L., Lor, K. L., Matuszewski, B., Melki, I., Mohr, B., Öksüz, I., Shahzad, R., Wang, C., Kitslaar, P. H., Unal, G., Katouzian, A., Orkisz, M., Chen, C. M., Precioso, F., Najman, L., Masood, S., Ünay, D., van Vliet, L., Moreno, R., Goldenberg, R., Vuçini, E., Krestin, G. P., Niessen, W. J., & van Walsum, T.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2013-12
Volume
17
Issue
8
Pages
859-876
ISSN
1361-8415 (ISSN-L)
OpenAlex
W2082304218
Cited by
205
References
2
FWCI
10.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography. https://app.cochat.ai/papers/10.1016/j.media.2013.05.007
The paper
Kirişli, H. A., Schaap, M., Metz, C. T., Dharampal, A. S., Meijboom, W. B., Papadopoulou, S. L., Dedic, A., Nieman, K., de Graaf, M. A., Meijs, M. F. L., Cramer, M. J., Broersen, A., Cetin, S., Eslami, A., Flórez-Valencia, L., Lor, K. L., Matuszewski, B., Melki, I., Mohr, B., . . . van Walsum, T. (2013). Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography. Medical Image Analysis. https://doi.org/10.1016/j.media.2013.05.007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.