CoChat

Efficient and robust cell detection: A structured regression approach

Open access
Xie, Yuanpu, Xing, Fuyong, Shi, Xiaoshuang, Kong, Xiangfei, Su, Hai, Yang, Lin · 2018 · Medical Image Analysis
Cited by 146

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

HighllightsA highly efficient and effective fully residual convolutional neural network is proposed for cell detection.We validate the superiority of structured regression over the conventional pixel wise classification method for cell detection.We prove the robustness and generalization capability of our model using four datasets, each corresponding to a distinct staining method or image modality. Graphical abstract Figure. No Caption available. Abstract Efficient and robust cell detection serves as a critical prerequisite for many subsequent biomedical image analysis methods and computer‐aided diagnosis (CAD). It remains a challenging task due to touching cells, inhomogeneous background noise, and large variations in cell sizes and shapes. In addition, the ever‐increasing amount of available datasets and the high resolution of whole‐slice scanned images pose a further demand for efficient processing algorithms. In this paper, we present a novel structured regression model based on a proposed fully residual convolutional neural network for efficient cell detection. For each testing image, our model learns to produce a dense proximity map that exhibits higher responses at locations near cell centers. Our method only requires a few training images with weak annotations (just one dot indicating the cell centroids). We have extensively evaluated our method using four different datasets, covering different microscopy staining methods (e.g., H & E or Ki‐67 staining) or image acquisition techniques (e.g., bright‐filed image or phase contrast). Experimental results demonstrate the superiority of our method over existing state of the art methods in terms of both detection accuracy and running time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2017.07.003

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 146

Metadata

Authors
Xie, Y., Xing, F., Shi, X., Kong, X., Su, H., & Yang, L.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2018-02
Volume
44
Pages
245-254
ISSN
1361-8415 (ISSN-L)
OpenAlex
W2738582428
Cited by
146
References
20
FWCI
7.04
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficient and robust cell detection: A structured regression approach. https://app.cochat.ai/papers/10.1016/j.media.2017.07.003
The paper
Xie, Y., Xing, F., Shi, X., Kong, X., Su, H., & Yang, L. (2018). Efficient and robust cell detection: A structured regression approach. Medical Image Analysis. https://doi.org/10.1016/j.media.2017.07.003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.