CoChat

VP-Nets : Efficient automatic localization of key brain structures in 3D fetal neurosonography

Open access
Huang, Ruobing, Xie, Weidi, Alison Noble, J. · 2018 · Medical Image Analysis
Cited by 46

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

HighlightsWe propose VP‐Nets for brain structure localization in 3D fetal neurosonography.The proposed 2.5D CNN is memory efficient, producing a high resolution 3D output.Our model can handle structure overlap while keeping contextual information.Visualization of the trained VP‐Nets is described.VP‐Nets is compared with Random Forests and 3D U‐Nets. Graphical abstract Figure. No caption available. ABSTRACT Three‐dimensional (3D) fetal neurosonography is used clinically to detect cerebral abnormalities and to assess growth in the developing brain. However, manual identification of key brain structures in 3D ultrasound images requires expertise to perform and even then is tedious. Inspired by how sonographers view and interact with volumes during real‐time clinical scanning, we propose an efficient automatic method to simultaneously localize multiple brain structures in 3D fetal neurosonography. The proposed View‐based Projection Networks (VP‐Nets), uses three view‐based Convolutional Neural Networks (CNNs), to simplify 3D localizations by directly predicting 2D projections of the key structures onto three anatomical views. While designed for efficient use of data and GPU memory, the proposed VP‐Nets allows for full‐resolution 3D prediction. We investigated parameters that influence the performance of VP‐Nets, e.g. depth and number of feature channels. Moreover, we demonstrate that the model can pinpoint the structure in 3D space by visualizing the trained VP‐Nets, despite only 2D supervision being provided for a single stream during training. For comparison, we implemented two other baseline solutions based on Random Forest and 3D U‐Nets. In the reported experiments, VP‐Nets consistently outperformed other methods on localization. To test the importance of loss function, two identical models are trained with binary corss‐entropy and dice coefficient loss respectively. Our best VP‐Net model achieved prediction center deviation: 1.8 ± 1.4 mm, size difference: 1.9 ± 1.5 mm, and 3D Intersection Over Union (IOU): 63.2 ± 14.7% when compared to the ground truth. To make the whole pipeline intervention free, we also implement a skull‐stripping tool using 3D CNN, which achieves high segmentation accuracy. As a result, the proposed processing pipeline takes a raw ultrasound brain image as input, and output a skull‐stripped image with five detected key brain structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2018.04.004

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 46

Metadata

Authors
Huang, R., Xie, W., & Alison Noble, J.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2018-07
Volume
47
Pages
127-139
ISSN
1361-8415 (ISSN-L)
OpenAlex
W2801875418
Cited by
46
References
9
FWCI
2.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.