The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Abstract
In utero estimates of fetal weight were evaluated prospectively in 109 fetuses with the use of sonographic models developed in a previous study. This report confirms that the best in utero weight estimates result from the use of models based on measurements of head size, abdominal size, and femur length. Since the accuracy of these models (1 SD = 7.5%) is significantly better than those based on measurements of head and body (e.g., biparietal diameter, abdominal circumference), we recommend routine use of such models in obstetric sonography.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite many efforts to develop new models for calculating EFW, the three-parameters (HC, AC, FL) formula reported by Hadlock et al. 25 provided the best fetal weight estimates in a large study cohort 27 , and should be considered the method of choice for assessment of all fetuses, including those suspected to be either small or large 13 .”
From ISUOG Practice Guidelines (updated): performance of the routine mid‐trimester fetal ultrasound scan (2022) · cites this paper as [25]
In the citing paper
“Mid-trimester sonographic measurements can be used to identify anomalies of fetal size 25 .”
From ISUOG Practice Guidelines (updated): performance of the routine mid‐trimester fetal ultrasound scan (2022) · cites this paper as [25]
Citations
Cites
Fetal growth and perinatal viability in California.
Williams, R. L., Creasy, R. K., Cunningham, G. C., Hawes, W. E., Norris, F. D., & Tashiro, M. (1982) · PubMed · Cited by 807
Hadlock, F. P., Harrist, R. B., Carpenter, R. J., Deter, R. L., & Park, S. K. (1984) · Radiology · doi:10.1148/radiology.150.2.6691115 · Cited by 785
Self-citationAn evaluation of two equations for predicting fetal weight by ultrasound
Shepard, M. J., Richards, V. A., Berkowitz, R. L., Warsof, S. L., & Hobbins, J. C. (1982) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)32283-9 · Cited by 607
The estimation of fetal weight by computer-assisted analysis
Warsof, S. L., Gohari, P., Berkowitz, R. L., & Hobbins, J. C. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90058-8 · Cited by 355
The determinants of birth weight
Dougherty, C., & Jones, A. D. (1982) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(82)90627-5 · Cited by 124
Longitudinal studies of fetal growth with the use of dynamic image ultrasonography
Deter, R. L., Harrist, R. B., Hadlock, F. P., & Poindexter, A. N. (1982) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(82)90545-2 · Cited by 90
Self-citationNormal ultrasonic fetal weight curve.
Ott, W. J., & Doyle, S. (1982) · PubMed · Cited by 34
Warsof, S. L. (1977) · Cited by 12
Cited by
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006
Kiserud, T., Piaggio, G., Carroli, G., Widmer, M., Carvalho, J., Neerup Jensen, L., Giordano, D., Cecatti, J. G., Abdel Aleem, H., Talegawkar, S. A., et al. (2017) · PLOS Medicine · doi:10.1371/journal.pmed.1002220 · Cited by 729
ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth
Salomon, L. J., Alfirevic, Z., Da Silva Costa, F., Deter, R. L., Figueras, F., Ghi, T., Glanc, P., Khalil, A., Lee, W., Napolitano, R., et al. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20272 · Cited by 704
Self-citationSovio, U., White, I. R., Dacey, A., Pasupathy, D., & Smith, G. C. S. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00131-2 · Cited by 609
Endocrine disrupters as obesogens
Grün, F., & Blumberg, B. (2009) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2009.02.018 · Cited by 582
Metadata
- Authors
- Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K.
- Affiliations
- The University of Texas System (US)
- Corresponding author
- Hadlock, Frank P.
- ORCID
- Deter, Russell L.
- Venue
- American Journal of Obstetrics and Gynecology
- Publisher
- Elsevier BV
- Published
- 1985-02
- Volume
- 151
- Issue
- 3
- Pages
- 333-337
- ISSN
- 0002-9378 (ISSN-L)
- OpenAlex
- W1968532354
- Cited by
- 2,682
- References
- 8
- Citations by year
- 2026: 138 · 2025: 162 · 2024: 174 · 2023: 157 · 2022: 203 · 2021: 178 · 2020: 179 · 2019: 154 · 2018: 137 · 2017: 148 · 2016: 104 · 2015: 116 · 2014: 115 · 2013: 99 · 2012: 66
- FWCI
- 10.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- American Journal of Obstetrics and Gynecology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Keywords
- fetal weight estimation, femur length, head size, abdominal circumference, biparietal diameter, fetal biometry, obstetric sonography
- MeSH terms
- Abdomen, Biometry, Body Weight, Cephalometry, Female, Femur, Fetus, Humans, Pregnancy, Prospective Studies, Ultrasonography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study. https://app.cochat.ai/papers/10.1016/0002-9378(85)90298-4
- The paper
- Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985). Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study. American Journal of Obstetrics and Gynecology. https://doi.org/10.1016/0002-9378(85)90298-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.