CoChat

Automated diagnosis of breast ultrasonography images using deep neural networks

Qi, Xiaofeng, Zhang, Lei, Chen, Yao, Pi, Yong, Chen, Yi, Lv, Qing, Yi, Zhang · 2019 · Medical Image Analysis
Cited by 235

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

HighlightsA breast cancer diagnosis model is developed.A method is proposed by using deep neural networks together with a region enhance mechanism and a cross training algorithm.The proposed method can identify malignant tumors and recognize solid nodules. Graphical abstract Figure. No caption available. ABSTRACT Ultrasonography images of breast mass aid in the detection and diagnosis of breast cancer. Manually analyzing ultrasonography images is time‐consuming, exhausting and subjective. Automated analyzing such images is desired. In this study, we develop an automated breast cancer diagnosis model for ultrasonography images. Traditional methods of automated ultrasonography images analysis employ hand‐crafted features to classify images, and lack robustness to the variation in the shapes, size and texture of breast lesions, leading to low sensitivity in clinical applications. To overcome these shortcomings, we propose a method to diagnose breast ultrasonography images using deep convolutional neural networks with multi‐scale kernels and skip connections. Our method consists of two components: the first one is to determine whether there are malignant tumors in the image, and the second one is to recognize solid nodules. In order to let the two networks work in a collaborative way, a region enhance mechanism based on class activation maps is proposed. The mechanism helps to improve classification accuracy and sensitivity for both networks. A cross training algorithm is introduced to train the networks. We construct a large annotated dataset containing a total of 8145 breast ultrasonography images to train and evaluate the models. All of the annotations are proven by pathological records. The proposed method is compared with two state‐of‐the‐art approaches, and outperforms both of them by a large margin. Experimental results show that our approach achieves a performance comparable to human sonographers and can be applied to clinical scenarios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2018.12.006

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Research works printed but not linked: 1

  1. Simonyan, K., Zisserman, A., 2014. Very deep convolutional networks for large-scale image recognition. arXiv:1409.1556. · arXiv

Cited by

Metadata

Authors
Qi, X., Zhang, L., Chen, Y., Pi, Y., Chen, Y., Lv, Q., & Yi, Z.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2019-02
Volume
52
Pages
185-198
ISSN
1361-8415 (ISSN-L)
OpenAlex
W2906658447
Cited by
235
References
36
FWCI
11.46
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Funders
National Natural Science Foundation of China (61432012, U1435213)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.