Breast MRI and X-ray mammography registration using gradient values
Open accessAbstract
Breast magnetic resonance imaging (MRI) and X-ray mammography are two image modalities widely used for early detection and diagnosis of breast diseases in women. The combination of these modalities, traditionally done using intensity-based registration algorithms, leads to a more accurate diagnosis and treatment, due to the capability of co-localizing lesions and susceptibles areas between the two image modalities. In this work, we present the first attempt to register breast MRI and X-ray mammographic images using intensity gradients as the similarity measure. Specifically, a patient-specific biomechanical model of the breast, extracted from the MRI image, is used to mimic the mammographic acquisition. The intensity gradients of the glandular tissue are directly projected from the 3D MRI volume to the 2D mammographic space, and two different gradient-based metrics are tested to lead the registration, the normalized cross-correlation of the scalar gradient values and the gradient correlation of the vectoral gradients. We compare these two approaches to an intensity-based algorithm, where the MRI volume is transformed to a synthetic computed tomography (pseudo-CT) image using the partial volume effect obtained by the glandular tissue segmentation performed by means of an Expectation-Maximization algorithm. This allows us to obtain the digitally reconstructed radiographies by a direct intensity projection. The best results are obtained using the scalar gradient approach along with a transversal isotropic material model, obtaining a target registration error (TRE), in millimeters, of 5.65 ± 2.76 for CC- and of 7.83 ± 3.04 for MLO-mammograms, while the TRE is 7.33 ± 3.62 in the 3D MRI. We also evaluate the effect of the glandularity of the breast as well as the landmark position on the TRE, obtaining moderated correlation values (0.65 and 0.77 respectively), concluding that these aspects need to be considered to increase the accuracy in further approaches.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Registration between breast MRI and X-ray mammography is feasible through a volume-preserving affine transformation model or gradient-based registration methods, reaching accuracy on the order of 10 mm.
“The registration between breast MRI and X-ray mammography has shown to be feasible through a properly defined volume-preserving affine transformation model (Mertzanidou et al. 2012) or through gradient-based registration methods (García et al. 2019). Both algorithms are able to reach registration accuracy in the order of 10mm.”
From Towards 2D/3D Registration of the Preoperative MRI to Intraoperative Fluoroscopic Images for Visualisation of Bone Defects (2023) · cites this paper as García et al. 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 36
- Azar, F.S. , Metaxas, D.N. , Schnall, M.D. , 2001. A deformable finite element model of the breast for predicting mechanical deformations under external perturbations. Acad. Radiol. 8 (10), 965-975 .
- Van der Bom, M. , Pluim, J. , Gounis, M. , van de Kraats, E. , Sprinkhuizen, S. , Tim- mer, J. , Homan, R. , Bartels, L. , 2011. Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data. Phys. Med. Biol. 56 (4), 1031 .
- Bonet, J. , Wood, R. , 1997. Nonlinear Continuum Mechanics for Finite Element Anal- ysis. Cambridge University Press .
- Boone, J.M. , Fewell, T.R. , Jennings, R.J. , 1997. Molybdenum, rhodium, and tung- sten anode spectral models using interpolating polynomials with application to mammography. Med. Phys. 24 (12), 1863-1874 .
- Chung , 2008. Modelling mammographic mechanics. University of Auckland, New Zealand Phd thesis .
- Eiben, B. , Vavourakis, V. , Hipwell, J.H. , Kabus, S. , Lorenz, C. , Buelow, T. , Hawkes, D.J. , 2014. Breast deformation modelling: comparison of methods to obtain a patient specific unloaded configuration. In: In SPIE Medical Imaging: Image-Guided Pro- cedures, Robotic Interventions, and Modeling, Vol. 9036, p. 903615 .
- Fiaschetti, V. , Pistolese, C. , Funel, V. , Rascioni, M. , Claroni, G. , Della Gatta, F. , Cossu, E. , Perretta, T. , Simonetti, G. , 2013. Breast MRI artefacts: evaluation and solutions in 630 consecutive patients. Clin. Radiol. 68 (11), e601-e608 .
- Fung, Y. , 1993. Biomechanics: Mechanical Properties of Living Tissues, 2nd Springer .
- Gan, R. , Chung, A.C. , Liao, S. , 2008. Maximum distance-gradient for robust image registration. Med. Image Anal. 12 (4), 452-468 .
- García, E. , Diez, Y. , Diaz, O. , Lladó, X. , Gubern-Mérida, A. , Martí, R. , Martí, J. , Oliver, A. , 2018b. Multimodal breast parenchymal patters correlation using a pa- tient-specific biomechanical model. IEEE Trans. Med. Imaging 37 (3), 712-723 .
- García, E. , Diez, Y. , Diaz, O. , Lladó, X. , Martí, R. , Martí, J. , Oliver, A. , 2018a. A step-by-step review on patient-specific biomechanical finite elements models for breast MRI to x-ray mammography registration. Med. Phys. 45 (1), e6-e31 .
- García, E. , Oliver, A. , Diez, Y. , Diaz, O. , Georgii, J. , Gubern-Mérida, A. , Martí, J. , Martí, R. , 2015. Comparing Regional Breast Density Using Full-field Digital Mam- mograms and Magnetic Resonance Imaging: a Preliminary Study. In: MICCAI Workshop on Breast Image Analysis, pp. 33-41 .
- García, E. , Oliver, A. , Diez, Y. , Diaz, O. , Gubern-Mérida, A. , Martí, R. , Martí, J. , 2017. Mapping 3D Breast Lesions from Full-field Digital Mammograms Using Sub- ject-specific Finite Element Models. In: SPIE Medical Imaging, Proc. SPIE, Vol. 10135, pp. 1013504O1-1013504O8 .
- Gubern-Mérida, A. , Kallenberg, M. , Martí, R. , Karssemeijer, N. , 2012. Segmentation of the pectoral muscle in breast MRI using atlas-based approaches. Medical Image Computing and Computer-Assisted Intervention, MICCAI. Springer Berlin Heidel- berg. .
- Han, L. , Hipwell, J. , Tanner, C. , Taylor, Z. , Mertzanidou, T. , Cardoso, J. , Ourselin, S. , Hawkes, D. , 2012. Development of patient-specific biomechanical models for predicting large breast deformation. Phys. Med. Biol. 57 (2), 455-472 .
- Herrmann, L.R. , 1976. Laplacian-isoparametric grid generation scheme. J. Eng. Mech. Div. 102 (5), 749-907 .
- Hopp, T. , Duric, N. , Ruiter, N. , 2012. Automatic multimodal 2D/3D image fusion of ultrasound computer tomography and x-ray mammography for breast cancer diagnosis. In: Proc. SPIE Medical Imaging, Vol. 8320 . 8320-1-8
- Kirkpatrick, S. , Vecchi, M.P. , et al. , 1983. Optimization by simmulated annealing. Sci- ence 220 (4598), 671-680 .
- Kwok, S.M. , Chandrasekhar, R. , Attikiouzel, Y. , Rickard, M.T. , 2004. Automatic pec- toral muscle segmentation on mediolateral oblique view mammograms. IEEE Trans. Med. Imaging 23 (9), 1129-1140 .
- Lagae, A. , Dutré, P. , 2008. Compact, fast and robust grids for ray tracing. Comput. Graphics Forum 27 (4), 1235-1244 .
- Livyatan, H. , Yaniv, Z. , Joskowicz, L. , 2003. Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT. IEEE Trans. Med. Imaging 22 (11), 1395-1406 .
- Lorensen, W. , Cline, H. , 1987. Marching cubes: a high resolution 3D surfaces con- struction algorithm. ACM Comput. Graphics 21 (4), 163-169 .
- Markelj, P. , Tomaževic, D. , Pernuš, F. , Likar, B. , 2008. Robust gradient-based 3-D/2-D registration of CT and MR to X-ray images. IEEE Trans. Med. Imaging 27 (12), 1704-1714 .
- Mertzanidou, T. , Hipwell, J. , Johnsen, S. , Han, L. , Einben, B. , Taylor, Z. , Ourselin, S. , Huisman, H. , Mann, R. , Bick, U. , Kaissermeijer, N. , Hawkes, D.J. , 2014. MRI to X-ray mammography intensity-based registration with simultaneous optimisa- tion of pose and biomechanical transformation parameters. Med. Image Anal. 18 (4), 674-683 .
- Mertzanidou, T. , Hipwell, J. , Tanner, C. , Hawkes, D. , 2010. An intensity-based ap- proach to x-ray mammography-MRI registration. In: Proc. SPIE Medical Imag- ing, Vol. 7623 . 7623-1-8
- Mertzanidou, T. , Hipwell, J. , Cardoso, M.J. , Zhang, X. , Tanner, C. , Ourselin, S. , Bick, U. , Huisman, H. , Karssemeijer, N. , Hawkes, D. , 2012. Mri to x-ray mammography registration using a volume-preserving affine transformation. Med. Image Anal. 16 (5), 966-975 .
- Otsu, N. , 1975. A threshold selection method from gray-level histograms. Automatica 11 (285-296), 23-27 .
- Pluim, J.P. , Maintz, J.A. , Viergever, M.A. , 20 0 0. Image registration by maximization of combined mutual information and gradient information. In: International Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, Berlin, Heidelberg, pp. 452-461 .
- Ruiter, N. , Müller, T. , Stotzka, R. , Gemmeke, H. , Reichenbach, J. , Kaiser, W. , 2003. Fi- nite element simulation of the breast's deformation during mammography to generate a deformation model for registration. In: Informatik aktuell -Bildver- arbeitung fur die Medizin, pp. 86-90 .
- Ruiter, N. , Stotzka, R. , Müller, T.O. , Gemmeke, H. , Reichenbach, J.R. , Kaiser, W.A. , 2006. Model-based registration of X-ray mammograms and MR images of the female breast. IEEE Trans. Nucl. Sci. 53 (1), 204-211 .
- Si, H. , 2015. Tetgen. a delaunay-based quality tetrahedral mesh generator. ACM Trans. Math. Softw. 41 (2), 11 .
- Tanner, C. , Degenhard, A. , Schnabel, J. , Smith, A.C. , Hayes, C. , Sonoda, L. , Leach, M. , Hose, D. , Hill, D. , Hawkes, D. , 2001. A method for the comparison of biome- chanical breast models. In: Mathematical Methods in Biomedical Image Analy- sis, 2001 MMBIA 2001. IEEE Workshop on. IEEE, pp. 11-18 .
- Tomaževi č, D. , Likar, B. , Slivnik, T. , Pernuš, F. , 2003. 3-D/2-D registration of CT and MR to X-ray images. IEEE Trans. Med. Imaging 22 (11), 1407-1416 .
- Wang, L. , Platel, B. , Ivanovskaya, T. , Harz, M. , Hahn, H.K. , 2012. Fully automatic breast segmentation in 3D breast MRI. In: Biomedical Imaging (ISBI), 2012 9th IEEE International Symposium on. IEEE, pp. 1024-1027 .
- Wein, W. , Röper, B. , Navab, N. , 2005. 2D/3D registration based on volume gra- dients. In: Medical Imaging. International Society for Optics and Photonics, pp. 144-150 .
- Wellman, P. , 1999. Tactile Imaging. Cambridge, MA: Harvard University's Division of Engineering and Applied Sciences Ph.d. thesis .
Cited by
Sorted by citations
Ku, P.-C., Martin-Gomez, A., Gao, C., Grupp, R., Mears, S. C., & Armand, M. (2023) · Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization · doi:10.1080/21681163.2022.2152375 · Cited by 8 · see citing works
“2012) or through gradient-based registration methods (Garćıa et al. 2019).”
Method
- Authors
- García, E., Diez, Y., Diaz, O., Lladó, X., Gubern-Mérida, A., Martí, R., Martí, J., & Oliver, A.
- Affiliations
- Universitat de Girona (ES)
- Corresponding author
- García, Eloy
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 54
- Pages
- 76-87
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2917571395
- Cited by
- 26
- References
- 0
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 8 · 2022: 1 · 2021: 2 · 2020: 8 · 2019: 3
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Medical Image Analysis (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Universitat de Girona Digital Repository (Universitat de Girona) (acceptedVersion, cc-by-nc-nd)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, cc-by-nc-nd)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (submittedVersion, other-oa)
- Funders
- University of Girona (MPC UdG 2016/022)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Keywords
- breast MRI, mammography, multimodal image registration, intensity gradient, gradient correlation, normalized cross-correlation, pseudo-CT, expectation-maximization algorithm, target registration error
- MeSH terms
- Algorithms, Breast, Breast Neoplasms, Contrast Media, Female, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, Mammography, Artifacts, Imaging, Three-Dimensional, Anatomic Landmarks, Multimodal Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review