We present a novel multi-task neural network called Temporal SonoEyeNet (TSEN) with a primary task to describe the visual navigation process of sonographers by learning to generate visual attention maps of ultrasound images around standard biometry planes of the fetal abdomen, head (trans-ventricular plane) and femur. TSEN has three components: a feature extractor, a temporal attention module (TAM), and an auxiliary video classification module (VCM). A soft dynamic time warping (sDTW) loss function is used to improve visual attention modelling. Variants of the model are trained on a dataset of 280 video clips, each containing one of the three biometry planes and lasting 3-7 seconds, with corresponding real-time recorded gaze tracking data of an experienced sonographer. We report the performances of the different variants of TSEN for visual attention prediction at standard biometry plane detection. The best model performance is achieved using bi-directional convolutional long-short term memory (biCLSTM) in both TAM and VCM, and it outperforms a previous spatial model on all static and dynamic saliency metrics. As an auxiliary task to validate the clinical relevance of the visual attention modelling, the predicted visual attention maps were used to guide standard biometry plane detection in consecutive US video frames. All spatio-temporal TSEN models achieve higher scores compared to a spatial-only baseline; the best performing TSEN model achieves F1 scores on these standard biometry planes of 83.7%, 89.9% and 81.1%, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2020.101762

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 41

Metadata

Authors
Cai, Y., Droste, R., Sharma, H., Chatelain, P., Drukker, L., Papageorghiou, A. T., & Noble, J. A.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2020-10
Volume
65
Pages
101762
ISSN
1361-8415 (ISSN-L)
OpenAlex
W3036634920
Cited by
41
References
10
FWCI
2.43
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spatio-temporal visual attention modelling of standard biometry plane-finding navigation. https://app.cochat.ai/papers/10.1016/j.media.2020.101762
The paper
Cai, Y., Droste, R., Sharma, H., Chatelain, P., Drukker, L., Papageorghiou, A. T., & Noble, J. A. (2020). Spatio-temporal visual attention modelling of standard biometry plane-finding navigation. Medical Image Analysis. https://doi.org/10.1016/j.media.2020.101762

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.