Autoencoder based self-supervised test-time adaptation for medical image analysis
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Deep neural networks have been successfully applied to medical image analysis tasks like segmentation and synthesis. However, even if a network is trained on a large dataset from the source domain, its performance on unseen test domains is not guaranteed. The performance drop on data obtained differently from the network’s training data is a major problem (known as domain shift) in deploying deep learning in clinical practice. Existing work focuses on retraining the model with data from the test domain, or harmonizing the test domain’s data to the network training data. A common practice is to distribute a carefully-trained model to multiple users (e.g., clinical centers), and then each user uses the model to process their own data, which may have a domain shift (e.g., varying imaging parameters and machines). However, the lack of availability of the source training data and the cost of training a new model often prevents the use of known methods to solve user-specific domain shifts. Here, we ask whether we can design a model that, once distributed to users, can quickly adapt itself to each new site without expensive retraining or access to the source training data? In this paper, we propose a model that can adapt based on a single test subject during inference. The model consists of three parts, which are all neural networks: a task model (T) which performs the image analysis task like segmentation; a set of autoencoders (AEs); and a set of adaptors (As). The task model and autoencoders are trained on the source dataset and can be computationally expensive. In the deployment stage, the adaptors are trained to transform the test image and its features to minimize the domain shift as measured by the autoencoders’ reconstruction loss. Only the adaptors are optimized during the testing stage with a single test subject thus is computationally efficient. The method was validated on both retinal optical coherence tomography (OCT) image segmentation and magnetic resonance imaging (MRI) T1-weighted to T2-weighted image synthesis. Our method, with its short optimization time for the adaptors (10 iterations on a single test subject) and its additional required disk space for the autoencoders (around 15 MB), can achieve significant performance improvement. Our code is publicly available at: https://github.com/YufanHe/self-domain-adapted-network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021) · Nature Methods · doi:10.1038/s41592-020-01008-z · Cited by 10,477
Image Style Transfer Using Convolutional Neural Networks
Gatys, L. A., Ecker, A. S., & Bethge, M. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.265 · Cited by 6,025
Adversarial Discriminative Domain Adaptation
Tzeng, E., Hoffman, J., Saenko, K., & Darrell, T. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.316 · Cited by 5,154
Learning Transferable Features with Deep Adaptation Networks
Long, M., Cao, Y., Wang, J., & Jordan, M. I. (2015) · arXiv · doi:10.48550/arxiv.1502.02791 · Cited by 4,505
CyCADA: Cycle-Consistent Adversarial Domain Adaptation
Hoffman, J., Tzeng, E., Park, T., Zhu, J.-Y., Isola, P., Saenko, K., Efros, A. A., & Darrell, T. (2017) · arXiv · doi:10.48550/arxiv.1711.03213 · Cited by 2,656
Gong, D., Liu, L., Le, V., Saha, B., Mansour, M. R., Venkatesh, S., & Van Den Hengel, A. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00179 · Cited by 1,930
OCGAN: One-Class Novelty Detection Using GANs With Constrained Latent Representations
Perera, P., Nallapati, R., & Xiang, B. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00301 · Cited by 608
Latent Space Autoregression for Novelty Detection
Abati, D., Porrello, A., Calderara, S., & Cucchiara, R. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00057 · Cited by 508
Cited by
SynthSeg: Segmentation of brain MRI scans of any contrast and resolution without retraining
Billot, B., Greve, D. N., Puonti, O., Thielscher, A., Van Leemput, K., Fischl, B., Dalca, A. V., & Iglesias, J. E. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102789 · Cited by 641
Federated learning for medical image analysis: A survey
Guan, H., Yap, P.-T., Bozoki, A., & Liu, M. (2024) · Pattern Recognition · doi:10.1016/j.patcog.2024.110424 · Cited by 518
Data drift in medical machine learning: implications and potential remedies
Sahiner, B., Chen, W., Samala, R. K., & Petrick, N. (2023) · The British Journal of Radiology · doi:10.1259/bjr.20220878 · Cited by 279
A Comprehensive Survey on Test-Time Adaptation Under Distribution Shifts
Liang, J., He, R., & Tan, T. (2025) · International Journal of Computer Vision · doi:10.1007/s11263-024-02181-w · Cited by 271
Artificial intelligence promotes the diagnosis and screening of diabetic retinopathy
Huang, X., Wang, H., She, C., Feng, J., Liu, X., Hu, X., Chen, L., & Tao, Y. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.946915 · Cited by 115
Metadata
- Authors
- He, Y., Carass, A., Zuo, L., Dewey, B. E., & Prince, J. L.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 72
- Pages
- 102136
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W3175770036
- Cited by
- 102
- References
- 19
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Autoencoder based self-supervised test-time adaptation for medical image analysis. https://app.cochat.ai/papers/10.1016/j.media.2021.102136
- The paper
- He, Y., Carass, A., Zuo, L., Dewey, B. E., & Prince, J. L. (2021). Autoencoder based self-supervised test-time adaptation for medical image analysis. Medical Image Analysis. https://doi.org/10.1016/j.media.2021.102136
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.