Breast cancer diagnosis using thermography and convolutional neural networks
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Thermography is an entirely non-invasive and non-contact imaging technique that is widely used in the medicinal field. Since the early detection of cancer is very important, the computer-aided system can increase the rate of diagnosis, cure, and survival of the affected person. Considering the high cost of treatment in addition to the high prevalence of affected persons, early diagnosis is the most important step in reducing the health and social complications of this disease. Currently, mammography is the main method used for screening breast cancer. However, for young woman, mammography is not recommended due to the low contrast that results from the dense breast, and alternative techniques must be considered for this purpose. Breast cancer is the main cause of cancer-related mortality among women. Early detection of cancer-especially breast cancer-will aid the treatment process. Our goal is to develop software for detecting breast cancer automatically that uses image-processing techniques and algorithms to analyze thermal breast images to detect the signs of the disease in these images, allowing the early detection of breast cancer. A new algorithm is proposed for the extraction of the breast characteristic features based on bio-data, image analysis, and image statistics. These features have been extracted from the thermal images captured by a thermal camera, and will be used to classify the breast images as normal or suspected by using convolutional neural networks (CNNs) optimized by Bayes algorithm. By using our proposed algorithm, a 98.95% of accuracy rate was obtained for the thermal images in the dataset belonging to 140 individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Screening for breast cancer: U.S. Preventive Services Task Force recommendation statement
Siu, A. L., & on behalf of the U.S. Preventive Services Task Force (2016) · Annals of Internal Medicine · doi:10.7326/m15-2886 · Cited by 2,094
Travis, R. C., Balkwill, A., Fensom, G. K., Appleby, P. N., Reeves, G. K., Wang, X.-S., Roddam, A. W., Gathani, T., Peto, R., Green, J., et al. (2016) · Journal of the National Cancer Institute · doi:10.1093/jnci/djw169 · Cited by 192
Cited by
Deep and machine learning techniques for medical imaging-based breast cancer: A comprehensive review
Houssein, E. H., Emam, M. M., Ali, A. A., & Suganthan, P. N. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.114161 · Cited by 404
Breast cancer detection using deep learning: Datasets, methods, and challenges ahead
din, N. M. U., Dar, R. A., Rasool, M., & Assad, A. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106073 · Cited by 363
A framework for breast cancer classification using Multi-DCNNs
Ragab, D. A., Attallah, O., Sharkas, M., Ren, J., & Marshall, S. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104245 · Cited by 204
Metadata
- Authors
- Ekici, S., & Jawzal, H.
- Venue
- Medical Hypotheses
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 137
- Pages
- 109542
- ISSN
- 0306-9877 (ISSN-L)
- OpenAlex
- W2997797021
- Cited by
- 193
- References
- 2
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.