The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A comparison of physical properties and fuel cell performance of Nafion and zirconium phosphate/Nafion composite membranes
Abstract
Abstract The physiochemical properties of Nafion 115 and a composite Nafion 115/zirconium phosphate (∼25 wt.%) membranes are compared. The composite membrane takes up more water than Nafion at the same water activity. However, the proton conductivity of the composite membrane is slightly less than that for Nafion 115. Small angle X-ray scattering shows that the hydrophilic phase domains in the composite membrane are spaced further apart than in Nafion 115, and the composite membrane shows less restructuring with water uptake. Despite the lower proton conductivity of the composite membranes they display better fuel cell performance than Nafion 115 when the fuel cell is operated at reduced humidity conditions. It is suggested that the composite membrane has a greater rigidity that accounts for its improved fuel cell performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yang, C., Costamagna, P., Srinivasan, S., Benziger, J., & Bocarsly, A. B. (2001) · Journal of Power Sources · doi:10.1016/s0378-7753(01)00812-6 · Cited by 604
Self-citationThe water content dependence of electro-osmotic drag in proton-conducting polymer electrolytes
Zawodzinski, T. A., Davey, J., Valerio, J., & Gottesfeld, S. (1995) · Electrochimica Acta · doi:10.1016/0013-4686(94)00277-8 · Cited by 586
Water Uptake of Perfluorosulfonic Acid Membranes from Liquid Water and Water Vapor
Hinatsu, J. T., Mizuhata, M., & Takenaka, H. (1994) · Journal of The Electrochemical Society · doi:10.1149/1.2054951 · Cited by 518
Antonucci, P. L., Aricò, A. S., Cretı̀, P., Ramunni, E., & Antonucci, V (1999) · Solid State Ionics · doi:10.1016/s0167-2738(99)00206-4 · Cited by 436
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
A review of PEM fuel cell durability: Degradation mechanisms and mitigation strategies
Wu, J., Yuan, X. Z., Martin, J. J., Wang, H., Zhang, J., Shen, J., Wu, S., & Merida, W. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.06.006 · Cited by 1,587
Recent approaches to improve Nafion performance for fuel cell applications: A review
Karimi, M. B., Mohammadi, F., & Hooshyari, K. (2019) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2019.09.096 · Cited by 450
Water sorption, desorption and transport in Nafion membranes
Majsztrik, P. W., Satterfield, M. B., Bocarsly, A. B., & Benziger, J. B. (2007) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.06.022 · Cited by 348
Satterfield, M. B., Majsztrik, P. W., Ota, H., Benziger, J. B., & Bocarsly, A. B. (2006) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.20857 · Cited by 242
Metadata
- Authors
- YANG, C.
- Venue
- Journal of Membrane Science
- Publisher
- Elsevier BV
- Published
- 2004-07
- Volume
- 237
- Issue
- 1-2
- Pages
- 145-161
- ISSN
- 0376-7388 (ISSN-L)
- OpenAlex
- W2145127032
- Cited by
- 413
- References
- 4
- FWCI
- 25.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.