Switchable solvent based liquid phase microextraction of trace lead and cadmium from environmental and biological samples prior to graphite furnace atomic absorption spectrometry detection
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A switchable hydrophilicity solvent (SHS) based liquid phase microextraction (LPME) method was proposed for the preconcentration of trace Pb (II) and Cd (II) followed by graphite furnace atomic absorption spectrometry (GFAAS) detection. The SHS of protonated triethylamine carbonate (P-TEA-C) was synthesized and applied as the extractant, which is environmentally friendly and low cost. Pb (II) and Cd (II) in ammonium pyrrolidine dithiocarbamate (APDC) complex form was extracted into the triethylamine (TEA) phase by converting P-TEA-C to TEA. The vortex led to the rapid formation of fine droplets of the extractant in the aqueous solution, and enlarged contact surface between both immiscible liquids. The factors affecting the microextraction procedure, including sample pH, APDC concentration, volume of SHS and NaOH, sample volume and matrix effect were investigated. Under the optimal conditions, enrichment factor of 50 was achieved with consumption of 10 mL aqueous sample, and detection limits of 16 and 3.9 ng L−1 were obtained for Pb (II) and Cd (II), respectively. The accuracy of the proposed method was validated by the analysis of Certified Reference Materials of GSBZ50009-88 environmental water, GBW07605 tea and GBW07601(GSH-1) human hair. The method was also successfully applied for determination of Pb (II) and Cd (II) in water, tea and human hair samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of deep eutectic solvents applied in extraction and separation
Li, X., & Row, K. H. (2016) · Journal of Separation Science · doi:10.1002/jssc.201600633 · Cited by 455
Design and evaluation of switchable-hydrophilicity solvents
Vanderveen, J. R., Durelle, J., & Jessop, P. G. (2014) · Green Chem. · doi:10.1039/c3gc42164c · Cited by 251
Rivas, R. E., López-García, I., & Hernández-Córdoba, M. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0206-7 · Cited by 62
Alavi, L., Seidi, S., Jabbari, A., & Baheri, T. (2017) · New Journal of Chemistry · doi:10.1039/c7nj00922d · Cited by 37
Cited by
Switchable-hydrophilicity solvent liquid-liquid microextraction
Alshana, U., Hassan, M., Al-Nidawi, M., Yilmaz, E., & Soylak, M. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116025 · Cited by 90
Switchable hydrophilicity solvents in analytical chemistry. Five years of achievements
Bazel, Y., Rečlo, M., & Chubirka, Y. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105115 · Cited by 72
Kasa, N. A., Zaman, B. T., & Bakırdere, S. (2020) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d0ja00276c · Cited by 37
Chaikhan, P., Udnan, Y., Ampiah-Bonney, R. J., & Chaiyasith, W. C. (2023) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2023.105214 · Cited by 33
Zheng, Y., Huang, X., Ling, Y., Huang, W., Wang, J., Zheng, Z., Wang, X., & Wang, H. (2019) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2019.05.009 · Cited by 15
Metadata
- Authors
- Zhang, S., Chen, B., He, M., & Hu, B.
- Venue
- Microchemical Journal
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 139
- Pages
- 380-385
- ISSN
- 0026-265X (ISSN-L)
- OpenAlex
- W2790435358
- Cited by
- 64
- References
- 4
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.