Optimization of magnetic solid phase microextraction with CoFe2O4 nanoparticles unmodified for preconcentration of cadmium in environmental samples by flame atomic absorption spectrometry
Open accessThe DOI matches its Crossref record.
Abstract
A method of preconcentration based in the magnetic solid phase microextraction with CoFe2O4 nanoparticles for the determination of cadmium in oyster and water samples using flame atomic absorption spectrometry (FAAS). Magnetic nanomaterials ones have aroused a greater interest in the area of analytical chemistry because of the high area of material and separation facility of the adsorbent. The statistical significance variables, extraction time, nanoparticles mass, pH, eluent concentration and desorption time were evaluated using a fractional factorial design of two levels (25–1). Afterward, a design Doehlert was used to optimize the pre-concentration process. The best experimental conditions were: nanoparticles mass (25 mg), pH (10.0) and eluent concentration of 1.20 mol L−1. The method allowed the determination of cadmium with a LOD of 0.24 μg L−1 and LOQ of 0.80 μg L−1. The precision expressed as relative standard deviation (RSD) of 3.33% for cadmium concentration with 20 μg L−1, the accuracy of the method was confirmed by the analysis of materials certified reference NIST 1566b Oyster tissue, pre-concentration factor 31. The method was applied to the analysis of the oyster and water samples has determined the concentration of cadmium from 4.6 to 7.8 mg kg−1 for oyster and 2.75 to 4.8 μg L−1 for water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Sorouraddin, S. M., Farajzadeh, M. A., Dastoori, H., & Okhravi, T. (2021) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067319.2019.1686144 · Cited by 42
Caner, C., Ciftci, M. Y., Tabassum, S., Altundag, H., & Bulut, E. (2025) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2024.139836 · Cited by 14
Metadata
- Authors
- de S. Dias, F., Guarino, M. E. P. A., Costa Pereira, A. L., Pedra, P. P., de A. Bezerra, M., & Marchetti, S. G.
- Venue
- Microchemical Journal
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 146
- Pages
- 1095-1101
- ISSN
- 0026-265X (ISSN-L)
- OpenAlex
- W2913812352
- Cited by
- 64
- References
- 0
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of magnetic solid phase microextraction with CoFe2O4 nanoparticles unmodified for preconcentration of cadmium in environmental samples by flame atomic absorption spectrometry. https://app.cochat.ai/papers/10.1016/j.microc.2019.02.005
- The paper
- de S. Dias, F., Guarino, M. E. P. A., Costa Pereira, A. L., Pedra, P. P., de A. Bezerra, M., & Marchetti, S. G. (2019). Optimization of magnetic solid phase microextraction with CoFe2O4 nanoparticles unmodified for preconcentration of cadmium in environmental samples by flame atomic absorption spectrometry. Microchemical Journal. https://doi.org/10.1016/j.microc.2019.02.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.