CoChat

Novel low viscous hydrophobic deep eutectic solvents liquid-liquid microextraction combined with acid base induction for the determination of phthalate esters in the packed milk samples

Wang, XiuLi, Lu, Yinguang, Shi, Longyan, Yang, Dezhi, Yang, Yaling · 2020 · Microchemical Journal
Cited by 55

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

A quick and simple sample extraction method was demonstrated for the liquid-liquid microextraction of seven phthalate acid esters (PAEs) using acid-base induced deep eutectic solvent (DES) with vortex-mixing assistance. The binary and ternary DESs were prepared by a range of fatty acids (C8-C12) and menthol, which ones act as hydrogen bond donors and acceptors respectively. Fatty acids and menthol served as an extraction solvent and a pH-dependent phase based on the acid-base reaction caused by the adjustment of the pH of the solution. Additionally, the extraction efficiency of the deep eutectic solvent (DES) was improved by adding the emulsifier sodium hydroxide. Hydrochloric acid was used as a phase separation agent. Additionally, the key parameters were optimized through orthogonal array experimental design and statistical analysis. Under the optimal extraction conditions, good linearity of the method was obtained in the concentration range from 1 to100 μg mL−1 for phthalate esters, and preconcentration was completed within 5 min. The limits of detection (LODs) was 1.06–4.55 ng mL−1, respectively. The spiked recovery values of actual samples were in the range of 83.9%–107.0% with relative standard deviations (RSDs) of 1.63–4.44%. The quantification limits of the seven phthalates were 3.20 to 13.61 ng mL−1. Thus, the overall experimental results revealed the promise of deep eutectic solvent (DES) for support in determining phthalate acid esters (PAEs). Therefore, this method could be used for the determination of seven phthalate acid esters in packaged milk samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.microc.2020.105332

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Metadata

Authors
Wang, X., Lu, Y., Shi, L., Yang, D., & Yang, Y.
Venue
Microchemical Journal
Publisher
Elsevier BV
Published
2020-12
Volume
159
Pages
105332
ISSN
0026-265X (ISSN-L)
OpenAlex
W3046253613
Cited by
55
References
6
FWCI
4.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel low viscous hydrophobic deep eutectic solvents liquid-liquid microextraction combined with acid base induction for the determination of phthalate esters in the packed milk samples. https://app.cochat.ai/papers/10.1016/j.microc.2020.105332
The paper
Wang, X., Lu, Y., Shi, L., Yang, D., & Yang, Y. (2020). Novel low viscous hydrophobic deep eutectic solvents liquid-liquid microextraction combined with acid base induction for the determination of phthalate esters in the packed milk samples. Microchemical Journal. https://doi.org/10.1016/j.microc.2020.105332

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.