Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Novel solid-state sensor material for efficient cadmium(II) detection and capturing from wastewater

Shahat, Ahmed, Kubra, Khadiza Tul, Salman, Md. Shad, Hasan, Md. Nazmul, Hasan, Md. Munjur·2021·Microchemical Journal

Abstract

Abstract In this study, the novel functional ligand was synthesized and then successfully immobilized onto the inorganic silica for the fabrication of solid-state sensor for simultaneous detection and adsorption of cadmium (Cd(II)) ion from water samples. The fabricated sensor was formed optical colour upon addition of trace amount of Cd(II) ion at experimental conditions. Several experimental parameters such as sensor morphology, solution pH, colour optimization, detection limit, competing ions effect, desorption and maximum adsorption capacity was evaluated. The data clarified that the materials could detect the ultra-trace level of Cd(II) ion according to the limit of detection was 0.88 µg/L based on the false positives and false negatives with the propagation of uncertainties. The solution pH was exhibited the key role, and the suitable pH 7.0 were selected based on the signal intensity and adsorption efficiency. The competing ions were not adversely affected in the Cd(II) ion detection and adsorption operation. In addition, the signal intensity was observed only for the Cd(II) ion, and these were clarified the high selectivity towards the Cd(II) ion at this experimental conditions. In addition, the adsorption data were well fitted with the Langmuir adsorption model with monolayer coverage. The determined maximum adsorption was 176.19 mg/g, which was comparable with the other forms of materials. The solid-state sensor was exhibited the high reusability based on the desorption performances. The desorption was carried out using 0.20 M HCl and then the sensor was ready to use after rinsing with water without significant loss in its performances. Therefore, the proposed solid-state sensor has high possibility in the real wastewater.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.microc.2021.105967

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 241

Metadata

Authors
Shahat, A., Kubra, K. T., Salman, M. S., Hasan, M. N., & Hasan, M. M.
Venue
Microchemical Journal
Publisher
Elsevier BV
Published
2021-05
Volume
164
Pages
105967
ISSN
0026-265X (ISSN-L)
OpenAlex
W3124856500
Cited by
241
References
1
FWCI
10.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel solid-state sensor material for efficient cadmium(II) detection and capturing from wastewater. https://app.cochat.ai/papers/10.1016/j.microc.2021.105967
The paper
Shahat, A., Kubra, K. T., Salman, M. S., Hasan, M. N., & Hasan, M. M. (2021). Novel solid-state sensor material for efficient cadmium(II) detection and capturing from wastewater. Microchemical Journal. https://doi.org/10.1016/j.microc.2021.105967

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.