The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Novel solid-state sensor material for efficient cadmium(II) detection and capturing from wastewater
Abstract
Abstract In this study, the novel functional ligand was synthesized and then successfully immobilized onto the inorganic silica for the fabrication of solid-state sensor for simultaneous detection and adsorption of cadmium (Cd(II)) ion from water samples. The fabricated sensor was formed optical colour upon addition of trace amount of Cd(II) ion at experimental conditions. Several experimental parameters such as sensor morphology, solution pH, colour optimization, detection limit, competing ions effect, desorption and maximum adsorption capacity was evaluated. The data clarified that the materials could detect the ultra-trace level of Cd(II) ion according to the limit of detection was 0.88 µg/L based on the false positives and false negatives with the propagation of uncertainties. The solution pH was exhibited the key role, and the suitable pH 7.0 were selected based on the signal intensity and adsorption efficiency. The competing ions were not adversely affected in the Cd(II) ion detection and adsorption operation. In addition, the signal intensity was observed only for the Cd(II) ion, and these were clarified the high selectivity towards the Cd(II) ion at this experimental conditions. In addition, the adsorption data were well fitted with the Langmuir adsorption model with monolayer coverage. The determined maximum adsorption was 176.19 mg/g, which was comparable with the other forms of materials. The solid-state sensor was exhibited the high reusability based on the desorption performances. The desorption was carried out using 0.20 M HCl and then the sensor was ready to use after rinsing with water without significant loss in its performances. Therefore, the proposed solid-state sensor has high possibility in the real wastewater.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment of Alzheimer’s Disease with Clioquinol
Regland, B., Lehmann, W., Abedini, I., Blennow, K., Jonsson, M., Karlsson, I., Sjögren, M., Wallin, A., Xilinas, M., & Gottfries, C.-G. (2001) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000051288 · Cited by 220
Cited by
Sheikh, M. C., Hasan, M. M., Hasan, M. N., Salman, M. S., Kubra, K. T., Awual, M. E., Waliullah, R. M., Rasee, A. I., Rehan, A. I., Hossain, M. S., et al. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.122854 · Cited by 365
Self-citationAwual, M. E., Salman, M. S., Hasan, M. M., Hasan, M. N., Kubra, K. T., Sheikh, M. C., Rasee, A. I., Rehan, A. I., Waliullah, R. M., Hossain, M. S., et al. (2024) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2023.10.062 · Cited by 341
Self-citationRasee, A. I., Awual, E., Rehan, A. I., Hossain, M. S., Waliullah, R. M., Kubra, K. T., Sheikh, M. C., Salman, M. S., Hasan, M. N., Hasan, M. M., et al. (2023) · Surfaces and Interfaces · doi:10.1016/j.surfin.2023.103276 · Cited by 304
Self-citationHassan, J., Rajib, M. M. R., Khan, M. N.-E.-A., Khandaker, S., Zubayer, M., Ashab, K. R., Kuba, T., Marwani, H. M., Asiri, A. M., Hasan, M. M., et al. (2024) · Journal of Environmental Management · doi:10.1016/j.jenvman.2024.120206 · Cited by 88
Self-citation
Metadata
- Authors
- Shahat, A., Kubra, K. T., Salman, M. S., Hasan, M. N., & Hasan, M. M.
- Venue
- Microchemical Journal
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 164
- Pages
- 105967
- ISSN
- 0026-265X (ISSN-L)
- OpenAlex
- W3124856500
- Cited by
- 241
- References
- 1
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel solid-state sensor material for efficient cadmium(II) detection and capturing from wastewater. https://app.cochat.ai/papers/10.1016/j.microc.2021.105967
- The paper
- Shahat, A., Kubra, K. T., Salman, M. S., Hasan, M. N., & Hasan, M. M. (2021). Novel solid-state sensor material for efficient cadmium(II) detection and capturing from wastewater. Microchemical Journal. https://doi.org/10.1016/j.microc.2021.105967
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.