CoChat

Correlative SEM-Raman microscopy to reveal nanoplastics in complex environments

Open access
Schmidt, Ruth, Nachtnebel, Manfred, Dienstleder, Martina, Mertschnigg, Sabrina, Schroettner, Hartmuth, Zankel, Armin, Poteser, Michael, Hutter, Hans-Peter, Eppel, Wolfgang, Fitzek, Harald · 2021 · Micron
Cited by 67

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Nowadays “microplastics” (MPs) is an already well-known term and results of micro-sized particles found in consumer products or environments are regularly reported. However, studies of native MPs smaller than 1 μm, often referred to as nanoplastics (NPs), in analytically challenging environments are rare. In this study, a correlative approach between scanning electron microscopy and Raman microscopy is tested to meet the challenges of finding and identifying NPs in the 100 nm range in various environments, ranging from ideal (distilled water) to challenging (sea salt, human amniotic fluid). To test the viability of this approach in principle, standardized polystyrene beads (Ø 200 nm) are mixed into the various environments in different concentrations. Promising detection limits of 2 10−3 μg/L (distilled water), 20 μg/L (sea salt) and 200 μg/L (human amniotic fluid) are found. To test the approach in practices both sea salt and amniotic fluid are analysed for native NPs as well. Interestingly a nylon-NP was found in the amniotic fluid, maybe originating from the sampling device. However, the practical test reveals limitations, especially with regard to the reliable identification of unknown NPs by Raman microscopy, due to strong background signals from the environments. We conclude from this in combination with the excellent performance in distilled water that a combination of this approach with an advanced sample preparation technique would yield a powerful tool for the analysis of NPs in various environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.micron.2021.103034

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 67

Metadata

Authors
Schmidt, R., Nachtnebel, M., Dienstleder, M., Mertschnigg, S., Schroettner, H., Zankel, A., Poteser, M., Hutter, H.-P., Eppel, W., & Fitzek, H.
Venue
Micron
Publisher
Elsevier BV
Published
2021-05
Volume
144
Pages
103034
ISSN
0968-4328 (ISSN-L)
OpenAlex
W3132068216
Cited by
67
References
2
FWCI
1.98
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlative SEM-Raman microscopy to reveal nanoplastics in complex environments. https://app.cochat.ai/papers/10.1016/j.micron.2021.103034
The paper
Schmidt, R., Nachtnebel, M., Dienstleder, M., Mertschnigg, S., Schroettner, H., Zankel, A., Poteser, M., Hutter, H.-P., Eppel, W., & Fitzek, H. (2021). Correlative SEM-Raman microscopy to reveal nanoplastics in complex environments. Micron. https://doi.org/10.1016/j.micron.2021.103034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.