Evaluation of the FilmArray™ Meningitis/Encephalitis panel with focus on bacteria and Cryptococcus spp
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
PURPOSE: Molecular methods provide fast and accurate detection of both bacteria and viruses in the cerebrospinal fluid (CSF) causing infection in the central nervous system (CNS). In the present study we evaluated the bacterial detection performance of the fully automated FilmArray™ Meningitis/Encephalitis (ME) panel (bioMérieux) by comparing it with culture and multiplexed in-house PCR. METHODS: Three sample types were analysed; Contrived samples with known bacterial/fungal concentration (n = 29), clinical samples from patients with verified cause of CNS infection (n = 17) and external quality assessment (EQA) samples (n = 11). Another six samples were purposely prepared with multiple targets to evaluate multiplex capacity. RESULTS: The FilmArray™ had a slightly higher limit of detection for Streptococcus pneumoniae, Neisseria meningitidis, Listeria monocytogenes and Streptococcus agalactiae compared to in-house PCR methods but performed equal or better when compared to culture. The FilmArray™ ME panel detected the expected pathogen in 17 of 17 clinical samples and yielded detection of three additional viruses of which one was confirmed with comparator techniques. All but one of the EQA samples were correctly detected. CONCLUSIONS: The results of this study are promising and the FilmArray™ ME panel could add to the diagnostic algorithm in CNS-infections. However, the limit of detection for the important pathogens N. meningitidis and S. pneumoniae could be improved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leber, A. L., Everhart, K., Balada-Llasat, J.-M., Cullison, J., Daly, J., Holt, S., Lephart, P., Salimnia, H., Schreckenberger, P. C., DesJarlais, S., et al. (2016) · Journal of Clinical Microbiology · doi:10.1128/jcm.00730-16 · Cited by 609 · cited 3×
“We used in-house PCRs as comparator method and not only Gram stain and culture (Wootton et al., 2016; Leber et al., 2016).”
BackgroundMethodResultDilemmas in the diagnosis of acute community-acquired bacterial meningitis
Brouwer, M. C., Thwaites, G. E., Tunkel, A. R., & van de Beek, D. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61185-4 · Cited by 302 · cited 1×
“The pathogen panorama is diverse and clinical assessment solely is not sufficient to discriminate between bacterial and/or viral origin (Brouwer et al., 2012).”
BackgroundLiesman, R. M., Strasburg, A. P., Heitman, A. K., Theel, E. S., Patel, R., & Binnicker, M. J. (2018) · Journal of Clinical Microbiology · doi:10.1128/jcm.01927-17 · Cited by 186
Green, D. A., Pereira, M., Miko, B., Radmard, S., Whittier, S., & Thakur, K. (2018) · Clinical Infectious Diseases · doi:10.1093/cid/ciy288 · Cited by 110 · cited 1×
“A low rate of HHV-6 positivity with the FilmArray™ ME panel that could not be confirmed and/or associated with disease has been observed in previous studies (Leber et al., 2016; O'Halloran et al., 2018; Green et al., 2018) also leading to inappropriate treatment (O'Halloran et al., 2018).”
ResultWootton, S. H., Aguilera, E., Salazar, L., Hemmert, A. C., & Hasbun, R. (2016) · Annals of Clinical Microbiology and Antimicrobials · doi:10.1186/s12941-016-0137-1 · Cited by 65
Eichinger, A., Hagen, A., Meyer-Bühn, M., & Huebner, J. (2019) · Infection · doi:10.1007/s15010-018-1212-7 · Cited by 60 · cited 1×
“In advantage, the FilmArray™ ME panel might be effective even after initiation of antibacterial treatment (not evaluated in this study) and the decreased turn-around time might have a positive impact on antimicrobial stewardship (Soucek et al., 2017; Eichinger et al., 2018).”
BackgroundGomez, C. A., Pinsky, B. A., Liu, A., & Banaei, N. (2017) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofw245 · Cited by 53
Cited by
Vetter, P., Schibler, M., Herrmann, J. L., & Boutolleau, D. (2020) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2019.12.013 · Cited by 64
Cailleaux, M., Pilmis, B., Mizrahi, A., Lourtet-Hascoet, J., Nguyen Van, J.-C., Alix, L., Couzigou, C., Vidal, B., Tattevin, P., & Le Monnier, A. (2020) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-019-03724-7 · Cited by 36
Pfefferle, S., Christner, M., Aepfelbacher, M., Lütgehetmann, M., & Rohde, H. (2020) · BMC Infectious Diseases · doi:10.1186/s12879-020-4904-4 · Cited by 36
Rapid Diagnostic Tests for Meningitis and Encephalitis—BioFire
Fleischer, E., & Aronson, P. L. (2020) · Pediatric Emergency Care · doi:10.1097/pec.0000000000002180 · Cited by 28
“False-negative results for viruses may be due to specimens containing low viral loads(31) and to the lower ability of the ME Panel to detect viruses when compared with some singleplex assays.(15,29,58,59) With regard to false-positive results, there are concerns for the potential of contamination during collection and…”
Etiology of Central Nervous System Infections in a Rural Area of Nepal Using Molecular Approaches
Säll, O., Thulin Hedberg, S., Neander, M., Tiwari, S., Dornon, L., Bom, R., Lagerqvist, N., Sundqvist, M., & Mölling, P. (2019) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.18-0434 · Cited by 20
Self-citation
Metadata
- Authors
- Nestor, D., Thulin Hedberg, S., Lignell, M., Skovbjerg, S., Mölling, P., & Sundqvist, M.
- Venue
- Journal of Microbiological Methods
- Publisher
- Elsevier BV
- Published
- 2019-02
- Volume
- 157
- Pages
- 113-116
- ISSN
- 0167-7012 (ISSN-L)
- OpenAlex
- W2910422488
- Cited by
- 15
- References
- 7
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the FilmArray™ Meningitis/Encephalitis panel with focus on bacteria and Cryptococcus spp. https://app.cochat.ai/papers/10.1016/j.mimet.2019.01.003
- The paper
- Nestor, D., Thulin Hedberg, S., Lignell, M., Skovbjerg, S., Mölling, P., & Sundqvist, M. (2019). Evaluation of the FilmArray™ Meningitis/Encephalitis panel with focus on bacteria and Cryptococcus spp. Journal of Microbiological Methods. https://doi.org/10.1016/j.mimet.2019.01.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.