A simple noise correction scheme for diffusional kurtosis imaging
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose Diffusional kurtosis imaging (DKI) is sensitive to the effects of signal noise due to strong diffusion weightings and higher order modeling of the diffusion weighted signal. A simple noise correction scheme is proposed to remove the majority of the noise bias in the estimated diffusional kurtosis. Methods Weighted linear least squares (WLLS) fitting together with a voxel-wise, subtraction-based noise correction from multiple, independent acquisitions are employed to reduce noise bias in DKI data. The method is validated in phantom experiments and demonstrated for in vivo human brain for DKI-derived parameter estimates. Results As long as the signal-to-noise ratio (SNR) for the most heavily diffusion weighted images is greater than 2.1, errors in phantom diffusional kurtosis estimates are found to be less than 5 percent with noise correction, but as high as 44 percent for uncorrected estimates. In human brain, noise correction is also shown to improve diffusional kurtosis estimates derived from measurements made with low SNR. Conclusion The proposed correction technique removes the majority of noise bias from diffusional kurtosis estimates in noisy phantom data and is applicable to DKI of human brain. Features of the method include computational simplicity and ease of integration into standard WLLS DKI post-processing algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 4×
“In order to more accurately characterize the DWI signal from restricted diffusion that occurs in biological tissues [12], DKI employs a more complicated signal model that includes higher order terms in the b-value, which typically requires the use of larger maximum b-values [10,11,13].”
BackgroundMethodSelf-citationMRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251 · cited 5×
“Diffusional kurtosis imaging (DKI) is an increasingly utilized diffusion MRI technique, which extends DTI by relaxing the assumption that the displacement of water via diffusion in biological tissue follows a Gaussian distribution (NB: the distribution of water displacements should not be confused with the noise distr…”
BackgroundMethodSelf-citationEcho-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Cited by
Diffusion MRI noise mapping using random matrix theory
Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26059 · Cited by 773
Rosenkrantz, A. B., Padhani, A. R., Chenevert, T. L., Koh, D., De Keyzer, F., Taouli, B., & Le Bihan, D. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24985 · Cited by 381
Quantitative assessment of diffusional kurtosis anisotropy
Glenn, G. R., Helpern, J. A., Tabesh, A., & Jensen, J. H. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3271 · Cited by 113
Self-citationHutchinson, E. B., Avram, A. V., Irfanoglu, M. O., Koay, C. G., Barnett, A. S., Komlosh, M. E., Özarslan, E., Schwerin, S. C., Juliano, S. L., & Pierpaoli, C. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26575 · Cited by 73
“Corrections for the effects of noise are also included as options in the DKI modeling implementation (4) as either a simplified noise floor removal process (37) or the option to smooth the DWI data, which will reduce the effects of signal variance.”
Glenn, G. R., Kuo, L. W., Chao, Y. P., Lee, C. Y., Helpern, J. A., & Jensen, J. H. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4714 · Cited by 58
Self-citation
Metadata
- Authors
- Glenn, G. R., Tabesh, A., & Jensen, J. H.
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 33
- Issue
- 1
- Pages
- 124-133
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W2085708716
- Cited by
- 43
- References
- 3
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple noise correction scheme for diffusional kurtosis imaging. https://app.cochat.ai/papers/10.1016/j.mri.2014.08.028
- The paper
- Glenn, G. R., Tabesh, A., & Jensen, J. H. (2015). A simple noise correction scheme for diffusional kurtosis imaging. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2014.08.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.