CoChat

A study of neurite orientation dispersion and density imaging in ischemic stroke

Wang, Zhenxiong, Zhang, Shun, Liu, Chengxia, Yao, Yihao, Shi, Jingjing, Zhang, Ju, Qin, Yuanyuan, Zhu, Wenzhen · 2019 · Magnetic Resonance Imaging
Cited by 49

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

OBJECTIVES To demonstrate the feasibility of the neurite orientation dispersion and density imaging (NODDI) technique in characterizing the microstructural changes in brain tissues during ischemic stroke and to compare its sensitivity with diffusion tensor imaging (DTI) and diffusion kurtosis imaging (DKI). METHODS Seventy-one patients with hyperacute/acute/subacute ischemic stroke were enrolled in the study. A multishell diffusion magnetic resonance imaging (dMRI) protocol was performed for each subject. Diffusion data were analyzed using the NODDI and diffusional kurtosis estimator toolboxes. Then, NODDI metrics between the lesions and the contralateral tissues were compared to evaluate their values in ischemic stroke. NODDI metrics among different stroke periods and the correlations between NODDI and the duration since stroke onset were analyzed as well. To compare the NODDI's sensitivity with established diffusion techniques, paired t-tests were performed to determine the absolute percentage changes of diffusion metrics between NODDI and DTI/DKI. RESULTS Compared with the contralateral tissues, lesions showed significantly increased values of intracellular volume fraction (Vic) and orientation dispersion index (ODI) and decreased values of isotropic volume fraction (Viso). ODI value was significantly different among three periods and showed fair to good positive correlation with the duration since stroke onset (R = 0.450). NODDI metrics showed significantly larger absolute percentage changes than that of DTI and DKI (P < 0.05, respectively). CONCLUSION NODDI allowed efficient evaluation of microstructural changes in brain tissues during ischemic stroke and showed increased sensitivity compared with DTI and DKI. The possible biophysical mechanisms underlying ischemia could be further elucidated using this advanced diffusion technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.mri.2018.10.018

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Wang, Z., Zhang, S., Liu, C., Yao, Y., Shi, J., Zhang, J., Qin, Y., & Zhu, W.
Venue
Magnetic Resonance Imaging
Publisher
Elsevier BV
Published
2019-04
Volume
57
Pages
28-33
ISSN
0730-725X (ISSN-L)
OpenAlex
W2899247639
Cited by
49
References
17
FWCI
2.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.