The DOI matches its Crossref record; the references it cites are not checked yet.
An experimental investigation of humidity and temperature effects on the mechanical properties of perfluorosulfonic acid membrane
Open accessOverview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Experimental measurements of the inelastic expansion strain due to membrane swelling suggest a magnitude of the order of 0.01 per unit λ in unreinforced membranes.
“Experimental measurements of the inelastic expansion strain due to membrane swelling suggest a magnitude of the order of 0.01 per unit λ in unreinforced membranes [1,39,150];”
From Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review (2020) · cites this paper as [150]
Citations
The citation lists haven’t been fetched yet
References 12 · Cited by 316
Research works printed but not linked: 10
- Y. Tang, M.H. Santare, A.M. Karlsson, S. Cleghorn, W.B. Johnson, J. Fuel Cell Sci. Technol., in press.
- Liu, 2001, J. New Mater. Electrochem. Syst., 4, 227
- Webber, 2004, AIChE J., 50, 3215, 10.1002/aic.10230 · DOI · Paper page
- Y. Tang, M.H. Santare, A.M. Karlsson, S. Cleghorn, W.B. Johnson, Proceeding of the Third International Conference on Fuel Cell Science, Engineering and Technology, Ypsilanti, Michigan, May 23–25, 2005.
- J.T. Uan-Zo-li, The effects of structure, humidity and aging on the mechanical properties of polymeric ionomers for fuel cell applications, Master Thesis, Virginia Tech., 2001.
- McDonald, 2004, Fuel Cell, 4, 208, 10.1002/fuce.200400015 · DOI
- Daniels, 1989, vol. 2
- Yeo, 1977, J. Appl. Polym. Sci., 21, 875, 10.1002/app.1977.070210401 · DOI
- Liu, 1998, Polym. Eng. Sci., 38
- Zawodzinski, 1993, J. Eletrochem. Soc., 140, 1041, 10.1149/1.2056194 · DOI · Paper page
Metadata
- Authors
- Tang, Y., Karlsson, A. M., Santare, M. H., Gilbert, M., Cleghorn, S., & Johnson, W. B.
- Affiliations
- University of Delaware (US)
- Corresponding author
- Karlsson, Anette M.
- ORCID
- Santare, Michael H.
- Venue
- Materials Science and Engineering: A
- Publisher
- Elsevier BV
- Published
- 2006-06
- Volume
- 425
- Issue
- 1-2
- Pages
- 297-304
- ISSN
- 0921-5093 (ISSN-L)
- OpenAlex
- W2028422519
- Cited by
- 316
- References
- 12
- Citations by year
- 2026: 14 · 2025: 16 · 2024: 17 · 2023: 13 · 2022: 12 · 2021: 15 · 2020: 15 · 2019: 20 · 2018: 14 · 2017: 9 · 2016: 16 · 2015: 16 · 2014: 21 · 2013: 15 · 2012: 22
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Materials Science and Engineering A (publishedVersion)
- EngagedScholarship @ Cleveland State University (Cleveland State University) (submittedVersion)
- Funders
- U.S. Department of Energy
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
- Physical Sciences › Chemical Engineering › Filtration and Separation › Membrane Separation and Gas Transport
- Physical Sciences › Chemical Engineering › Filtration and Separation › Membrane-based Ion Separation Techniques
- Keywords
- perfluorosulfonic acid membranes, proton exchange membranes, humidity effects, temperature effects, mechanical properties, Young's modulus, yield strength, dimensional change, tensile properties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review