CoChat

Osseointegration of porous apatite-wollastonite and poly(lactic acid) composite structures created using 3D printing techniques

Open access
Tcacencu, Ion, Rodrigues, Natacha, Alharbi, Naif, Benning, Matthew, Toumpaniari, Sotiria, Mancuso, Elena, Marshall, Martyn, Bretcanu, Oana, Birch, Mark, McCaskie, Andrew, Dalgarno, Kenneth · 2018 · Materials Science and Engineering: C
Cited by 46

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A novel apatite-wollastonite/poly(lactic acid) (AW/PLA) composite structure, which matches cortical and cancellous bone properties has been produced and evaluated in vitro and in vivo. The composites structure has been produced using an innovative combination of 3D printed polymer and ceramic macrostructures, thermally bonded to create a hybrid composite structure. In vitro cell assays demonstrated that the AW structure alone, PLA structure alone, and AW/PLA composite were all biocompatible, with the AW structure supporting the proliferation and osteogenic differentiation of rat bone marrow stromal cells. Within a rat calvarial defect model the AW material showed excellent osseointegration with the formation of new bone, and vascularisation of the porous AW structure, both when the AW was implanted alone and when it was part of the AW/PLA composite structure. However, the AW/PLA structure showed the largest amount of the newly formed bone in vivo, an effect which is considered to be a result of the presence of the osteoinductive AW structure stimulating bone growth in the larger pores of the adjacent PLA structure. The layered AW/PLA structure showed no signs of delamination in any of the in vitro or in vivo studies, a result which is attributed to good initial bonding between polymer and ceramic, slow resorption rates of the two materials, and excellent osseointegration. It is concluded that macro-scale composites offer an alternative route to the fabrication of bioactive bone implants which can provide a match to both cortical and cancellous bone properties over millimetre length scales.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.msec.2018.04.022

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 46

Metadata

Authors
Tcacencu, I., Rodrigues, N., Alharbi, N., Benning, M., Toumpaniari, S., Mancuso, E., Marshall, M., Bretcanu, O., Birch, M., McCaskie, A., & Dalgarno, K.
Venue
Materials Science and Engineering: C
Publisher
Elsevier BV
Published
2018-09
Volume
90
Pages
1-7
ISSN
0928-4931 (ISSN-L)
OpenAlex
W2797414949
Cited by
46
References
2
FWCI
1.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Osseointegration of porous apatite-wollastonite and poly(lactic acid) composite structures created using 3D printing techniques. https://app.cochat.ai/papers/10.1016/j.msec.2018.04.022
The paper
Tcacencu, I., Rodrigues, N., Alharbi, N., Benning, M., Toumpaniari, S., Mancuso, E., Marshall, M., Bretcanu, O., Birch, M., McCaskie, A., & Dalgarno, K. (2018). Osseointegration of porous apatite-wollastonite and poly(lactic acid) composite structures created using 3D printing techniques. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2018.04.022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.