The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparison of 3D-printed porous tantalum and titanium scaffolds on osteointegration and osteogenesis
Abstract
Metals such as Ta (tantalum) and Ti (titanium) have been popularly used as a bone substitute or implants in orthopedic surgery and dentistry, since they have excellent corrosion. For manufacturing porous implants with precise structure, SLM (Selective laser melting), which is one of the 3D (three-dimensional) printing techniques, is always be chosen. To compare biological performances between porous Ta and Ti implants, we designed them with the same porosity, pore shape, pore size, and pore distribution via CAD (computer aided design), and then produced them by SLM. It was shown that the equivalent stress of porous Ta and Ti were 393.62 ± 1.39 MPa and 139.75 ± 14.50 MPa, and their Young's modulus were 3.10 ± 0.03GPa and 5.42 ± 0.07GPa, respectively. Meanwhile, we investigated their biological performance with hBMMSCs (human Bone marrow mesenchymal stem cells) in vitro. The results revealed that both two scaffolds were in favor of hBMMSCs proliferation and osteogenic differentiation. In addition, porous scaffolds were implanted in the femur bone defects rabbits in vivo showed the both porous scaffolds were beneficial to the bone ingrowth and bone-implant fixation. In summary, porous Ta has an equivalent biological performance as traditional porous Ti implants in small bone defect repair. Taken together, porous Ta is a promising material for bone regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Li, Y., Yang, W., Li, X., Zhang, X., Wang, C., Meng, X., Pei, Y., Fan, X., Lan, P., Wang, C., et al. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b00331 · Cited by 210
Self-citationMesenchymal stem cells: mechanisms and role in bone regeneration
Qin, Y., Guan, J., & Zhang, C. (2014) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2013-132387 · Cited by 122
Cited by
Khorsandi, D., Fahimipour, A., Abasian, P., Saber, S. S., Seyedi, M., Ghanavati, S., Ahmad, A., De Stephanis, A. A., Taghavinezhaddilami, F., Leonova, A., et al. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.12.044 · Cited by 428
Tissue Engineering and Regenerative Medicine: Achievements, Future, and Sustainability in Asia
Han, F., Wang, J., Ding, L., Hu, Y., Li, W., Yuan, Z., Guo, Q., Zhu, C., Yu, L., Wang, H., et al. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00083 · Cited by 357
Self-citationPharmaceutical electrospinning and 3D printing scaffold design for bone regeneration
Wang, Z., Wang, Y., Yan, J., Zhang, K., Lin, F., Xiang, L., Deng, L., Guan, Z., Cui, W., & Zhang, H. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.007 · Cited by 344
Articular cartilage and osteochondral tissue engineering techniques: Recent advances and challenges
Wei, W., & Dai, H. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.05.011 · Cited by 327
Metadata
- Authors
- Wang, H., Su, K., Su, L., Liang, P., Ji, P., & Wang, C.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 104
- Pages
- 109908
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2962094614
- Cited by
- 169
- References
- 2
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of 3D-printed porous tantalum and titanium scaffolds on osteointegration and osteogenesis. https://app.cochat.ai/papers/10.1016/j.msec.2019.109908
- The paper
- Wang, H., Su, K., Su, L., Liang, P., Ji, P., & Wang, C. (2019). Comparison of 3D-printed porous tantalum and titanium scaffolds on osteointegration and osteogenesis. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2019.109908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.