Culture-free diagnostics of Pseudomonas aeruginosa infection by silver nanorod array based SERS from clinical sputum samples
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Pseudomonas aeruginosa can cause major infection in immunocompromised patients, and successful antibiotic treatment of the infection relies on accurate and rapid identification of the infectious agents. Here, we reported a culture-free diagnostic method based on the surface-enhanced Raman spectroscopy (SERS) of pyocyanin (PCN), a major biomarker of P. aeruginosa. This platform can detect PCN as low as 5 ppb or 2.38 × 10−8 mol L−1 in both aqueous solutions and spiked clinical sputum samples. It has also been used to dynamically monitor the excretion of PCN by P. aeruginosa during its growth. The presence of PCN has been detected by SERS in 15 clinical sputum samples, which indicates P. aeruginosa infection, with 95.6% sensitivity and 93.3% specificity. The system can advantageously process multiple specimens rapidly, overcomes the need for bacterial culture and diagnostic microbiology assays, and have widespread implications in the early detection of P. aeruginosa infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wilson, R., Sykes, D. A., Watson, D., Rutman, A., Taylor, G. W., & Cole, P. J. (1988) · Infection and Immunity · doi:10.1128/iai.56.9.2515-2517.1988 · Cited by 374
Phenazine-1-carboxylic acid promotes bacterial biofilm development via ferrous iron acquisition
Wang, Y., Wilks, J. C., Danhorn, T., Ramos, I., Croal, L., & Newman, D. K. (2011) · Journal of Bacteriology · doi:10.1128/jb.00396-11 · Cited by 239
Cited by
SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Bodelón, G., Montes-García, V., López-Puente, V., Hill, E. H., Hamon, C., Sanz-Ortiz, M. N., Rodal-Cedeira, S., Costas, C., Celiksoy, S., Pérez-Juste, I., et al. (2016) · Nature Materials · doi:10.1038/nmat4720 · Cited by 359
Recent advances in hepatocellular carcinoma therapy
Dutta, R., & Mahato, R. I. (2017) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2017.02.010 · Cited by 280
The application of Raman spectroscopy for the detection and identification of microorganisms
Stöckel, S., Kirchhoff, J., Neugebauer, U., Rösch, P., & Popp, J. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4844 · Cited by 260
Sensing the unreachable: challenges and opportunities in biofilm detection
Xu, Y., Dhaouadi, Y., Stoodley, P., & Ren, D. (2020) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2019.10.009 · Cited by 119
Metadata
- Authors
- Wu, X., Chen, J., Li, X., Zhao, Y., & Zughaier, S. M.
- Venue
- Nanomedicine: Nanotechnology, Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2014-11
- Volume
- 10
- Issue
- 8
- Pages
- 1863-1870
- ISSN
- 1549-9634 (ISSN-L)
- OpenAlex
- W2015726464
- Cited by
- 97
- References
- 2
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.