The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Photothermally tunable biodegradation of implantable triboelectric nanogenerators for tissue repairing
Abstract
Abstract Implantable triboelectric nanogenerators (iTENGs) are promising to work as sustainable power source for implanted healthcare electronic devices. In this study, we fabricated a serial of biodegradable (BD) iTENGs and effectively tuned their degradation process in vivo by employing Au nanorods (AuNRs), which responded to the near-infrared (NIR) light sensitively. The implanted BD-iTENG worked well for more than 28 days in vivo, without NIR treatment. When NIR treatment was applied, the output of AuNRs-BD-iTENG rapidly reduced to 0 within 24 h and the device was mostly degraded in 14 days. This showed that the in vivo degradation of our BD-iTENG could be triggered and come into effect very quickly with rational manipulation. The peak value of in vitro and in vivo output voltage generated by the AuNRs-BD-iTENG were 28 V and 2 V, respectively. Moreover, the in vivo output voltage was applied on fibroblast cells and demonstrated a significant acceleration for cell migration across the scratch, which was very beneficial to wound healing process. In addition, we discovered that the alternating BD-iTENG output was as efficient as direct current (DC) stimuli. The mechanisms were investigated. Our work has demonstrated the feasibility of building a photothermally tunable BD-iTENG as a transient power source for biomedical healthcare electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Self-citation
Cited by
Choi, D., Lee, Y., Lin, Z.-H., Cho, S., Kim, M., Ao, C. K., Soh, S., Sohn, C., Jeong, C. K., Lee, J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12458 · Cited by 656
Self-citationWang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
Design, manufacturing and applications of wearable triboelectric nanogenerators
Wang, H., Han, M., Song, Y., & Zhang, H. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105627 · Cited by 179
Metadata
- Authors
- Li, Z., Feng, H., Zheng, Q., Li, H., Zhao, C., Ouyang, H., Noreen, S., Yu, M., Su, F., Liu, R., Li, L., Wang, Z. L., & Li, Z.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 54
- Pages
- 390-399
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W2897912498
- Cited by
- 166
- References
- 1
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photothermally tunable biodegradation of implantable triboelectric nanogenerators for tissue repairing. https://app.cochat.ai/papers/10.1016/j.nanoen.2018.10.020
- The paper
- Li, Z., Feng, H., Zheng, Q., Li, H., Zhao, C., Ouyang, H., Noreen, S., Yu, M., Su, F., Liu, R., Li, L., Wang, Z. L., & Li, Z. (2018). Photothermally tunable biodegradation of implantable triboelectric nanogenerators for tissue repairing. Nano Energy. https://doi.org/10.1016/j.nanoen.2018.10.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.