The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A facile respiration-driven triboelectric nanogenerator for multifunctional respiratory monitoring
Abstract
Abstract Respiration is an important physiological process of human body that can not only act as vital signs for physical health management or “biomarkers” of some diseases, but also as a kind of energy that can be utilized to drive triboelectric nanogenerator (TENG). It is particularly desirable to develop a facile TENG that can be driven by human respiration itself for multifunctional human respiratory monitoring. In this work, a respiration-driven TENG based on Ce-doped ZnO-PANI nanocomposite film that can convert respiratory airflow energy into electric signals was developed for the detection of multiple respiratory parameters including trace-level NH3 concentration, human respiratory flow and respiratory frequency. It was found that the as-designed TENG exhibited excellent ability for respiratory flow monitoring (2–6 L/min), identification of human breathing frequency and recognition of different breathing patterns. Furthermore, output voltage of the self-powered NH3 sensor monotonously decreases with the increase of NH3 concentrations from 0.1 to 25 ppm. Especially, a good NH3-sensing performance was exhibited when exposed to a trace-level NH3 atmosphere ranging from 0.1 to 1 ppm, implying a promising potential in self-powered disease screening related to the detection of exhaled NH3 in human breathing. This research offers a facile method to establish a multifunctional respiratory monitoring system driven by respiration itself, which is of significant importance in self-powered human health monitoring through non-implantable respiratory diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Wearable humidity sensor based on porous graphene network for respiration monitoring
Pang, Y., Jian, J., Tu, T., Yang, Z., Ling, J., Li, Y., Wang, X., Qiao, Y., Tian, H., Yang, Y., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.038 · Cited by 369
Cited by
Wang, D., Zhang, D., Yang, Y., Mi, Q., Zhang, J., & Yu, L. (2021) · ACS Nano · doi:10.1021/acsnano.0c09015 · Cited by 687
Shi, Q., Dong, B., He, T., Sun, Z., Zhu, J., Zhang, Z., & Lee, C. (2020) · InfoMat · doi:10.1002/inf2.12122 · Cited by 661
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Self-citationWang, D., Zhang, D., Li, P., Yang, Z., Mi, Q., & Yu, L. (2021) · Nano-Micro Letters · doi:10.1007/s40820-020-00580-5 · Cited by 471
Material aspects of triboelectric energy generation and sensors
Kim, D. W., Lee, J. H., Kim, J. K., & Jeong, U. (2020) · NPG Asia Materials · doi:10.1038/s41427-019-0176-0 · Cited by 428
Metadata
- Authors
- Wang, S., Tai, H., Liu, B., Duan, Z., Yuan, Z., Pan, H., Su, Y., Xie, G., Du, X., & Jiang, Y.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 58
- Pages
- 312-321
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W2910194597
- Cited by
- 202
- References
- 2
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.