The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Abstract
In mammals, physiological respiration involves respiratory cycles of inhaled and exhaled breaths, which has traditionally been an underutilized resource potentially encompassing a wealth of physiologically relevant information as well as clues to potential diseases. Recently, triboelectric nanogenerators (TENGs) have been widely adopted for self‐powered respiration monitoring owing to their compelling features, such as decent biocompatibility, wearing comfort, low‐cost, and high sensitivity to respiration activities in the aspect of low frequency and slight amplitude body motions. Physiological respiration behaviors and exhaled chemical regents can be precisely and continuously monitored by TENG‐based respiration sensors for personalized health care. This article presents an overview of TENG enabled self‐powered respiration monitoring, with a focus on the working principle, sensing materials, functional structures, and related applications in both physical respiration motion detection and chemical breath analysis. Concepts and approaches for acquisition of physical information associated with respiratory rate and depth are covered in the first part. Then the sensing mechanism, theoretical modeling, and applications related to detection of chemicals released from breathing gases are systemically summarized. Finally, the opportunities and challenges of triboelectric effect enabled self‐powered respiration monitoring are comprehensively discussed and criticized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655
Machine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516
Wearable humidity sensor based on porous graphene network for respiration monitoring
Pang, Y., Jian, J., Tu, T., Yang, Z., Ling, J., Li, Y., Wang, X., Qiao, Y., Tian, H., Yang, Y., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.038 · Cited by 369
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Oh, J. Y., Lee, J. H., Han, S. W., Chae, S. S., Bae, E. J., Kang, Y. H., Choi, W. J., Cho, S. Y., Lee, J.-O., Baik, H. K., et al. (2016) · Energy & Environmental Science · doi:10.1039/c5ee03813h · Cited by 289
Bai, P., Zhu, G., Jing, Q., Yang, J., Chen, J., Su, Y., Ma, J., Zhang, G., & Wang, Z. L. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201401267 · Cited by 282
Self-citation
Cited by
Choi, D., Lee, Y., Lin, Z.-H., Cho, S., Kim, M., Ao, C. K., Soh, S., Sohn, C., Jeong, C. K., Lee, J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12458 · Cited by 656
Self-citationSmart Gas Sensors: Recent Developments and Future Prospective
Zong, B., Wu, S., Yang, Y., Li, Q., Tao, T., & Mao, S. (2025) · Nano-Micro Letters · doi:10.1007/s40820-024-01543-w · Cited by 282
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
Flexible Metasurfaces for Multifunctional Interfaces
Zhou, Y., Wang, S., Yin, J., Wang, J., Manshaii, F., Xiao, X., Zhang, T., Bao, H., Jiang, S., & Chen, J. (2024) · ACS Nano · doi:10.1021/acsnano.3c09310 · Cited by 115
Self-citationLi, S., Jiang, J., Zhai, N., Liu, J., Feng, K., Chen, Y., Wen, Z., Sun, X., & Zhong, J. (2022) · Nano Energy · doi:10.1016/j.nanoen.2021.106870 · Cited by 80
Metadata
- Authors
- Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-07-08
- Volume
- 33
- Issue
- 35
- Pages
- e2101262-e2101262
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3181494176
- Cited by
- 481
- References
- 7
- FWCI
- 25.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator. https://app.cochat.ai/papers/10.1002/adma.202101262
- The paper
- Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021). Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator. Advanced Materials. https://doi.org/10.1002/adma.202101262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.