The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Expandable microsphere-based triboelectric nanogenerators as ultrasensitive pressure sensors for respiratory and pulse monitoring
Abstract
Abstract Physiological monitoring sensors have attracted increasing research interest due to their broad application potential in daily activities, sports performance and health status monitoring for next generation athletic/clinical technologies. Having high sensitivity and low power consumption are essential to realize these applications in advanced portable/remote forms. In this work, triboelectric nanogenerators (TENGs), which are based on expandable microspheres in a polydimethylsiloxane (PDMS) mixture, were constructed as self-powered pressure sensors with ultrahigh sensitivity for biological signal monitoring through a low-cost and simple processing technique. Different sensitivities can be obtained by adjusting the weight percentage of microspheres in the PDMS, and the output voltage of the sensor was analyzed by a theoretical model, which was consistent with the simulation results. The maximum sensitivity of the sensor can reach 150 mV/Pa so respiratory and pulse monitoring can be implemented by attaching the ultrasensitive pressure sensor to the chest and wrist of a human body, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yang, Y., Zhang, H., Lin, Z.-H., Zhou, Y. S., Jing, Q., Su, Y., Yang, J., Chen, J., Hu, C., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403838y · Cited by 798
Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring
Lin, Z., Chen, J., Li, X., Zhou, Z., Meng, K., Wei, W., Yang, J., & Wang, Z. L. (2017) · ACS Nano · doi:10.1021/acsnano.7b02975 · Cited by 494
Zi, Y., Lin, L., Wang, J., Wang, S., Chen, J., Fan, X., Yang, P., Yi, F., & Wang, Z. L. (2015) · Advanced Materials · doi:10.1002/adma.201500121 · Cited by 482
Cited by
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Cai, Y.-W., Zhang, X.-N., Wang, G.-G., Li, G.-Z., Zhao, D.-Q., Sun, N., Li, F., Zhang, H.-Y., Han, J.-C., & Yang, Y. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105663 · Cited by 338
Technology evolution from self-powered sensors to AIoT enabled smart homes
Dong, B., Shi, Q., Yang, Y., Wen, F., Zhang, Z., & Lee, C. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105414 · Cited by 313
Zhu, M., Yi, Z., Yang, B., & Lee, C. (2021) · Nano Today · doi:10.1016/j.nantod.2020.101016 · Cited by 295
Zhu, M., He, T., & Lee, C. (2020) · Applied Physics Reviews · doi:10.1063/5.0016485 · Cited by 287
Metadata
- Authors
- Liu, Z., Zhao, Z., Zeng, X., Fu, X., & Hu, Y.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 59
- Pages
- 295-301
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W2916580426
- Cited by
- 221
- References
- 3
- FWCI
- 8.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Expandable microsphere-based triboelectric nanogenerators as ultrasensitive pressure sensors for respiratory and pulse monitoring. https://app.cochat.ai/papers/10.1016/j.nanoen.2019.02.057
- The paper
- Liu, Z., Zhao, Z., Zeng, X., Fu, X., & Hu, Y. (2019). Expandable microsphere-based triboelectric nanogenerators as ultrasensitive pressure sensors for respiratory and pulse monitoring. Nano Energy. https://doi.org/10.1016/j.nanoen.2019.02.057
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.