The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultra-flexible and high-sensitive triboelectric nanogenerator as electronic skin for self-powered human physiological signal monitoring
Abstract
Abstract Electronic skin (E-skin) with tactile sensing characteristics has presented great potential in disease diagnosis and health assessment; however, the imperfect combination of ultra-flexibility and high-sensitivity have restricted its widespread application. Here, we report a contact-separation triboelectric-nanogenerator (CS-TENG) consisting of ultra-flexible micro-frustum-array polydimethylsiloxane (mf-PDMS) film and Cu electrodes as the basic friction units, which can achieve self-powered weak physiological signal monitoring with great comfort. The CS-TENG uses elastic mf-PDMS as both the major body and the friction layer to realize ultra-flexible and conformal contact with irregular human skin. By exploring the microelectromechanical system (MEMS) preparation process, a uniform and controllable mf-arrays structure was fabricated to utilize both the normal and shear stresses, thereby increasing friction and enhancing device sensitivity. The CS-TENG displays high sensitivity (5.67 V/105Pa), good linearity (R2 = 0.99 of voltage), high stability (more than 80000 cycles), and fast response time (60 ms). With these outstanding characteristics, the CS-TENG can sense subtle changes in wrist pulse under various physiological conditions, which can also be easily arranged into a 1 × 3 array to mimic the three-fingered pulse-taking in traditional Chinese medicine. This work provides a new way to prepare ultra-flexible and high-sensitive TENG as E-skin and demonstrates its potential application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Cited by
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Nanocomposite hydrogel-based strain and pressure sensors: a review
Sun, X., Yao, F., & Li, J. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta06965e · Cited by 420
Zarei, M., Lee, G., Lee, S. G., & Cho, K. (2023) · Advanced Materials · doi:10.1002/adma.202203193 · Cited by 345
Metadata
- Authors
- Yu, J., Hou, X., He, J., Cui, M., Wang, C., Geng, W., Mu, J., Han, B., & Chou, X.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 69
- Pages
- 104437
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W2997181112
- Cited by
- 182
- References
- 1
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultra-flexible and high-sensitive triboelectric nanogenerator as electronic skin for self-powered human physiological signal monitoring. https://app.cochat.ai/papers/10.1016/j.nanoen.2019.104437
- The paper
- Yu, J., Hou, X., He, J., Cui, M., Wang, C., Geng, W., Mu, J., Han, B., & Chou, X. (2020). Ultra-flexible and high-sensitive triboelectric nanogenerator as electronic skin for self-powered human physiological signal monitoring. Nano Energy. https://doi.org/10.1016/j.nanoen.2019.104437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.