The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Hierarchically structured PVDF/ZnO core-shell nanofibers for self-powered physiological monitoring electronics
Abstract
Abstract Piezoelectric-based wearable electronics promise potential applications in human physiological monitoring for disease prediction, diagnose and rehabilitation. Still, it is a big challenge to fulfill excellent compatibility and precisely monitoring of the complexly subtle physiological signals simultaneously. Here, we prepared a three-dimensional hierarchically interlocked PVDF/ZnO nanofiber-based piezoelectric sensor through epitaxial growing ZnO nano rods (NRs) on the surface of electrospun PVDF nanofibers, which enables the fiber-based physiological monitoring electronics (PME) of well flexibility and high gas permeability. Due to synergistic piezoelectric effect of the effectively deformed interlocked ZnO NRs and the uniformly orientated PVDF nanofibers with high electroactive phase, the sensitivities of PME in both pressing and bending modes have been greatly improved 6 times and 41 times than that of pure PVDF nanofibers respectively. On this basis, the designed PME can precisely detect the complexly subtle physiological signals of respiration, wrist pulse and muscle behavior. Moreover, a sensitive gait recognition system was successfully developed based on PME arrays. Therefore, this proposed fiber-based device provides an alternative strategy to monitor the human subtle physiological signals and demonstrates promising potential in the expanded application of healthcare and clinical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfibre–nanowire hybrid structure for energy scavenging
Qin, Y., Wang, X., & Wang, Z. L. (2008) · Nature · doi:10.1038/nature06601 · Cited by 1,610
Wang, X., Gu, Y., Xiong, Z., Cui, Z., & Zhang, T. (2014) · Advanced Materials · doi:10.1002/adma.201304248 · Cited by 1,398
Persano, L., Dagdeviren, C., Su, Y., Zhang, Y., Girardo, S., Pisignano, D., Huang, Y., & Rogers, J. A. (2013) · Nature Communications · doi:10.1038/ncomms2639 · Cited by 1,271
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow
Boutry, C. M., Beker, L., Kaizawa, Y., Vassos, C., Tran, H., Hinckley, A. C., Pfattner, R., Niu, S., Li, J., Claverie, J., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0336-5 · Cited by 862
Pang, Y., Zhang, K., Yang, Z., Jiang, S., Ju, Z., Li, Y., Wang, X., Wang, D., Jian, M., Zhang, Y., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07613 · Cited by 774
A Hybrid Piezoelectric Structure for Wearable Nanogenerators
Lee, M., Chen, C., Wang, S., Cha, S. N., Park, Y. J., Kim, J. M., Chou, L., & Wang, Z. L. (2012) · Advanced Materials · doi:10.1002/adma.201200150 · Cited by 619
Graphene Textile Strain Sensor with Negative Resistance Variation for Human Motion Detection
Yang, Z., Pang, Y., Han, X.-L., Yang, Y., Ling, J., Jian, M., Zhang, Y., Yang, Y., & Ren, T.-L. (2018) · ACS Nano · doi:10.1021/acsnano.8b03391 · Cited by 563
Dagdeviren, C., Joe, P., Tuzman, O. L., Park, K.-I., Lee, K. J., Shi, Y., Huang, Y., & Rogers, J. A. (2016) · Extreme Mechanics Letters · doi:10.1016/j.eml.2016.05.015 · Cited by 499
Deng, W., Yang, T., Jin, L., Yan, C., Huang, H., Chu, X., Wang, Z., Xiong, D., Tian, G., Gao, Y., et al. (2019) · Nano Energy · doi:10.1016/j.nanoen.2018.10.049 · Cited by 488
Self-citation
Cited by
Pyo, S., Lee, J., Bae, K., Sim, S., & Kim, J. (2021) · Advanced Materials · doi:10.1002/adma.202005902 · Cited by 631
Piezoelectric materials for flexible and wearable electronics: A review
Wu, Y., Ma, Y., Zheng, H., & Ramakrishna, S. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110164 · Cited by 521
Multistructured Electrospun Nanofibers for Air Filtration: A Review
Lu, T., Cui, J., Qu, Q., Wang, Y., Zhang, J., Xiong, R., Ma, W., & Huang, C. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c06520 · Cited by 447
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Self-citationSun, T., Feng, B., Huo, J., Xiao, Y., Wang, W., Peng, J., Li, Z., Du, C., Wang, W., Zou, G., et al. (2024) · Nano-Micro Letters · doi:10.1007/s40820-023-01235-x · Cited by 384
Metadata
- Authors
- Yang, T., Pan, H., Tian, G., Zhang, B., Xiong, D., Gao, Y., Yan, C., Chu, X., Chen, N., Zhong, S., Zhang, L., Deng, W., & Yang, W.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 72
- Pages
- 104706
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3010954634
- Cited by
- 377
- References
- 42
- FWCI
- 14.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hierarchically structured PVDF/ZnO core-shell nanofibers for self-powered physiological monitoring electronics. https://app.cochat.ai/papers/10.1016/j.nanoen.2020.104706
- The paper
- Yang, T., Pan, H., Tian, G., Zhang, B., Xiong, D., Gao, Y., Yan, C., Chu, X., Chen, N., Zhong, S., Zhang, L., Deng, W., & Yang, W. (2020). Hierarchically structured PVDF/ZnO core-shell nanofibers for self-powered physiological monitoring electronics. Nano Energy. https://doi.org/10.1016/j.nanoen.2020.104706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.