The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Self-powered wearable pressure sensing system for continuous healthcare monitoring enabled by flexible thin-film thermoelectric generator
Abstract
Abstract Flexible and portable pressure sensors with highly sensitive and cost-effective attributes are of great demand in wearable electronics, biomedical monitoring, and artificial intelligence. To realize portable pressure sensors with mobile operation, ultrathin, flexible, and sustainable power sources are highly desired. Here, a self-powered wearable pressure sensing system is developed by integrating a conductive elastomer-based pressure sensor with a flexible thin-film thermoelectric generator (tf-TEG) to harvest body heat. Laser engraving technique is adopted to achieve pressure sensor with tunable sensitivity through the controllable design of surface microstructures. To produce a reliable and renewable power supply for the pressure sensor, the flexible tf-TEG is constructed with high thermal-conductivity insulation films for heat absorbing and flexible hydrogels as heat sink, resulting in a large temperature gradient for high power generation. In particular, the pressure sensitivity of the self-powered system is independent of the temperature gradient across the tf-TEG, allowing it to maintain a stable performance under various temperature differences between human skin and surroundings. For the first time, the self-powered pressure sensing system proposed in this work enables continuous monitoring of human physiological signals and body motions entirely powered by the skin-attachable tf-TEG without an electronic boost circuitry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Fiber‐Based Wearable Electronics: A Review of Materials, Fabrication, Devices, and Applications
Zeng, W., Shu, L., Li, Q., Chen, S., Wang, F., & Tao, X. (2014) · Advanced Materials · doi:10.1002/adma.201400633 · Cited by 2,019
Wang, X., Gu, Y., Xiong, Z., Cui, Z., & Zhang, T. (2014) · Advanced Materials · doi:10.1002/adma.201304248 · Cited by 1,398
A wearable thermoelectric generator fabricated on a glass fabric
Kim, S. J., We, J. H., & Cho, B. J. (2014) · Energy & Environmental Science · doi:10.1039/c4ee00242c · Cited by 949
Pang, Y., Zhang, K., Yang, Z., Jiang, S., Ju, Z., Li, Y., Wang, X., Wang, D., Jian, M., Zhang, Y., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07613 · Cited by 774
Graphene-Paper Pressure Sensor for Detecting Human Motions
Tao, L.-Q., Zhang, K.-N., Tian, H., Liu, Y., Wang, D.-Y., Chen, Y.-Q., Yang, Y., & Ren, T.-L. (2017) · ACS Nano · doi:10.1021/acsnano.7b02826 · Cited by 738
Highly efficient and bending durable perovskite solar cells: toward a wearable power source
Kim, B. J., Kim, D. H., Lee, Y.-Y., Shin, H.-W., Han, G. S., Hong, J. S., Mahmood, K., Ahn, T. K., Joo, Y.-C., Hong, K. S., et al. (2015) · Energy & Environmental Science · doi:10.1039/c4ee02441a · Cited by 679
Microstructured Graphene Arrays for Highly Sensitive Flexible Tactile Sensors
Zhu, B., Niu, Z., Wang, H., Leow, W. R., Wang, H., Li, Y., Zheng, L., Wei, J., Huo, F., & Chen, X. (2014) · Small · doi:10.1002/smll.201401207 · Cited by 632
Yoon, J., Baca, A. J., Park, S.-I., Elvikis, P., Geddes, J. B., Li, L., Kim, R. H., Xiao, J., Wang, S., Kim, T.-H., et al. (2008) · Nature Materials · doi:10.1038/nmat2287 · Cited by 618
Wearable Flexible Sensors: A Review
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705700 · Cited by 526
Cited by
Thermoelectric converter: Strategies from materials to device application
Wu, Z., Zhang, S., Liu, Z., Mu, E., & Hu, Z. (2022) · Nano Energy · doi:10.1016/j.nanoen.2021.106692 · Cited by 280
Li, X., Liu, Y., Ding, Y., Zhang, M., Lin, Z., Hao, Y., Li, Y., & Chang, J. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c01042 · Cited by 79
Metadata
- Authors
- Wang, Y., Zhu, W., Deng, Y., Fu, B., Zhu, P., Yu, Y., Li, J., & Guo, J.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 73
- Pages
- 104773
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3016064181
- Cited by
- 253
- References
- 37
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-powered wearable pressure sensing system for continuous healthcare monitoring enabled by flexible thin-film thermoelectric generator. https://app.cochat.ai/papers/10.1016/j.nanoen.2020.104773
- The paper
- Wang, Y., Zhu, W., Deng, Y., Fu, B., Zhu, P., Yu, Y., Li, J., & Guo, J. (2020). Self-powered wearable pressure sensing system for continuous healthcare monitoring enabled by flexible thin-film thermoelectric generator. Nano Energy. https://doi.org/10.1016/j.nanoen.2020.104773
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.