The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A wearable thermoelectric generator fabricated on a glass fabric
Abstract
The conversion of body heat into electrical energy using a thermoelectric (TE) power generator is useful for wearable self-powered mobile electronic systems such as medical sensors or smart watches. We herein demonstrate a glass fabric-based flexible TE generator using a screen printing technique and the self-sustaining structure of a TE device without top and bottom substrates. With this technique it is possible to make the device thin (∼500 μm), lightweight (∼0.13 g cm−2), and flexible. In addition, the developed TE generator achieved an unprecedentedly large output power density which is several tens of times higher than that of flexible TE generators reported to date. The developed TE generator shows an allowable bending radius of as low as 20 mm and no change in performance by repeated bending for 120 cycles. This work can expedite the development of wearable self-powered mobile devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhanced thermoelectric performance of rough silicon nanowires
Hochbaum, A. I., Chen, R., Delgado, R. D., Liang, W., Garnett, E. C., Najarian, M., Majumdar, A., & Yang, P. (2008) · Nature · doi:10.1038/nature06381 · Cited by 4,109
Persano, L., Dagdeviren, C., Su, Y., Zhang, Y., Girardo, S., Pisignano, D., Huang, Y., & Rogers, J. A. (2013) · Nature Communications · doi:10.1038/ncomms2639 · Cited by 1,271
Cited by
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Metadata
- Authors
- Kim, S. J., We, J. H., & Cho, B. J.
- Venue
- Energy & Environmental Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 7
- Issue
- 6
- Pages
- 1959
- ISSN
- 1754-5692 (ISSN-L)
- 1754-5706
- OpenAlex
- W2169112538
- Cited by
- 949
- References
- 2
- FWCI
- 28.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A wearable thermoelectric generator fabricated on a glass fabric. https://app.cochat.ai/papers/10.1039/c4ee00242c
- The paper
- Kim, S. J., We, J. H., & Cho, B. J. (2014). A wearable thermoelectric generator fabricated on a glass fabric. Energy & Environmental Science. https://doi.org/10.1039/c4ee00242c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.