Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A wireless energy transmission enabled wearable active acetone biosensor for non-invasive prediabetes diagnosis

Su, Yuanjie, Yang, Tiannan, Zhao, Xun, Cai, Zhixiang, Chen, Guorui, Yao, Mingliang, Chen, Kyle, Bick, Michael, Wang, Jianjun, Li, Shuangding, Xie, Guangzhong, Tai, Huiling, Du, Xiaosong, Jiang, Yadong, Chen, Jun·2020·Nano Energy

Abstract

Abstract Approximately 22% of the 86 million people in the United States living with prediabetes are unaware of their condition. Detection of acetone in human respiration offers an effective and painless approach for the diagnosis of prediabetes. In this work, a wearable active acetone biosensor employing chitosan and reduced graphene oxide (RGO) as sensitive materials was developed to non-invasively diagnose prediabetes. When operated under 97.3% relative humidity at room temperature, the prepared chitosan and RGO composite film-based sensor exhibited a good sensing response of 27.89% under 10 ppm acetone in respiratory gases, which is about 5 times higher than the sensing response of pure chitosan film-based devices. In addition, finite element analysis and phase-field simulation were conducted to provide theoretical support for the active sensing mechanism. This work not only presents a wirelessly powered wearable active acetone biosensor, but also paves the way for a new method of non-invasive prediabetes diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2020.104941

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 250

Metadata

Authors
Su, Y., Yang, T., Zhao, X., Cai, Z., Chen, G., Yao, M., Chen, K., Bick, M., Wang, J., Li, S., Xie, G., Tai, H., Du, X., Jiang, Y., & Chen, J.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2020-08
Volume
74
Pages
104941
ISSN
2211-2855 (ISSN-L)
OpenAlex
W3024682297
Cited by
250
References
2
FWCI
16.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A wireless energy transmission enabled wearable active acetone biosensor for non-invasive prediabetes diagnosis. https://app.cochat.ai/papers/10.1016/j.nanoen.2020.104941
The paper
Su, Y., Yang, T., Zhao, X., Cai, Z., Chen, G., Yao, M., Chen, K., Bick, M., Wang, J., Li, S., Xie, G., Tai, H., Du, X., Jiang, Y., & Chen, J. (2020). A wireless energy transmission enabled wearable active acetone biosensor for non-invasive prediabetes diagnosis. Nano Energy. https://doi.org/10.1016/j.nanoen.2020.104941

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.