Self-powered cardiac pacemaker by piezoelectric polymer nanogenerator implant
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
Abstract Self-powered biomedical implants improve the life of patients and lower the risks associated with battery replacement. Piezoelectric energy harvesters that generate electricity from the cardiac motions are among the potential candidates to be used in self-powered implants, such as cardiac pacemakers. In this context, lead-based ceramic piezoelectric nanogenerators (PNGs) were emerged, which are toxic and susceptible to fatigue crack, causing harm to the patients. Polyvinylidene fluoride-trifluoroethylene (PVDF-TrFE)-based films were also developed as cardiac energy harvesters. Here, we show a battery-free heart pacemaker that is powered by the generated electricity of a biocompatible and flexible piezoelectric polymer-based nanogenerator (PNG) from the cardiac motions of the left ventricle. The PNG is comprised of composite nanofibers of poly(vinylidene fluoride) (PVDF) and a hybrid nanofiller made of zinc oxide (ZnO) and reduced graphene oxide (rGO). The composite nanofiber is optimized towards achieving a large power output. In vivo implanted optimized PNG can successfully harvest 0.487 μJ from every heartbeat, which is conveniently larger than the pacing threshold energy for the human heart. The successful demonstration of a self-powered pacemaker places the polymer-based PNGs among the viable candidates for self-powered biomedical implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation of Graphitic Oxide
Hummers, W. S., & Offeman, R. E. (1958) · Journal of the American Chemical Society · doi:10.1021/ja01539a017 · Cited by 29,920
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/5174 · Cited by 8,161
Left ventricular fibre architecture in man.
Greenbaum, R. A., Ho, S. Y., Gibson, D. G., Becker, A. E., & Anderson, R. H. (1981) · Heart · doi:10.1136/hrt.45.3.248 · Cited by 1,074
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073
Synthesis of clathrate cerium superhydride CeH9 at 80-100 GPa with atomic hydrogen sublattice
Salke, N. P., Davari Esfahani, M. M., Zhang, Y., Kruglov, I. A., Zhou, J., Wang, Y., Greenberg, E., Prakapenka, V. B., Liu, J., Oganov, A. R., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12326-y · Cited by 1,004
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Piezoelectric BaTiO3Thin Film Nanogenerator on Plastic Substrates
Park, K.-I., Xu, S., Liu, Y., Hwang, G.-T., Kang, S.-J. L., Wang, Z. L., & Lee, K. J. (2010) · Nano Letters · doi:10.1021/nl102959k · Cited by 827
Flexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Shi, K., Sun, B., Huang, X., & Jiang, P. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.07.053 · Cited by 517
Cited by
Functional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Piezoelectric energy harvesting systems for biomedical applications
Panda, S., Hajra, S., Mistewicz, K., In-na, P., Sahu, M., Rajaitha, P. M., & Kim, H. J. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107514 · Cited by 269
A review on polymers and their composites for flexible electronics
Li, L., Han, L., Hu, H., & Zhang, R. (2023) · Materials Advances · doi:10.1039/d2ma00940d · Cited by 256
Advanced Energy Harvesters and Energy Storage for Powering Wearable and Implantable Medical Devices
Gao, Z., Zhou, Y., Zhang, J., Foroughi, J., Peng, S., Baughman, R. H., Wang, Z. L., & Wang, C. H. (2024) · Advanced Materials · doi:10.1002/adma.202404492 · Cited by 231
Piezoelectric Biomaterials Inspired by Nature for Applications in Biomedicine and Nanotechnology
Chen, S., Tong, X., Huo, Y., Liu, S., Yin, Y., Tan, M., Cai, K., & Ji, W. (2024) · Advanced Materials · doi:10.1002/adma.202406192 · Cited by 208
Gao, Q., Agarwal, S., Greiner, A., & Zhang, T. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101139 · Cited by 175
Piezoelectric Energy Harvester Technologies: Synthesis, Mechanisms, and Multifunctional Applications
He, Q., & Briscoe, J. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c17037 · Cited by 171
Vijayakanth, T., Shankar, S., Finkelstein-Zuta, G., Rencus-Lazar, S., Gilead, S., & Gazit, E. (2023) · Chemical Society Reviews · doi:10.1039/d3cs00202k · Cited by 161
Metadata
- Authors
- Azimi, S., Golabchi, A., Nekookar, A., Rabbani, S., Amiri, M. H., Asadi, K., & Abolhasani, M. M.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 83
- Pages
- 105781
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3119529004
- Cited by
- 243
- References
- 57
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.